Instruction Manual
19
10) Status LED (0 to 15)
• Display while Mode 0 (Command Current Ratio Level) being selected
The command current ratio level of the motor rated current as 100% is displayed in a bar
graph with green lights.
{: LED Illuminating, × : LED OFF
Status of LEDs
15 × × × × × × × × × × × × × × × ×
{
14 × × × × × × × × × × × × × × ×
{ {
13 × × × × × × × × × × × × × ×
{ { {
12 × × × × × × × × × × × × ×
{ { { {
11 × × × × × × × × × × × ×
{ { { { {
10 × × × × × × × × × × ×
{ { { { { {
9 × × × × × × × × × ×
{ { { { { { {
8 × × × × × × × × ×
{ { { { { { { {
7 × × × × × × × ×
{ { { { { { { { {
6 × × × × × × ×
{ { { { { { { { { {
5 × × × × × ×
{ { { { { { { { { { {
4 × × × × ×
{ { { { { { { { { { { {
3 × × × ×
{ { { { { { { { { { { { {
2 × × ×
{ { { { { { { { { { { { { {
1 × ×
{ { { { { { { { { { { { { { {
0 ×
{ { { { { { { { { { { { { { { {
Command
Current
Ratio [%]
0
to 6.24
to 12.24
to 18.74
to 24.99
to 31.24
to 37.49
to 43.74
to 49.99
to 56.24
to 62.49
to 68.74
to 74.99
to 81.24
to 87.49
to 93.74
to 100.00
• Display while Mode 1 (Alarm Code) being selected [refer to Chapter 7 for Alarm Codes]
The alarm code issued in ERC3 is displayed in the hexadecimal system with the LED 0 to
15 used as 1 word of bit 0 to 15.
(Example) If Alarm Code “083” (absolute position movement command at home-return
incomplete) is generated, the display is as shown below:
{: LED Illuminating, × : LED OFF
LED 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Alarm Display × × × × × × × ×
{
× × × × ×
{ {
Alarm Code 0 0 8 3