Owner's manual
Table Of Contents
- Cover
- Please Read Before Use
- CAUTION
- CE Marking
- Table of Contents
- Safety Guide
- Caution in Handling
- 1. Overview
- 2. Installation
- 3. Wiring
- 3.1 Basic Structure
- 3.2 Configuration Using a SIO Converter
- 3.3 Configuration Using an Isolated PIO Terminal Block
- 3.4 Configuration Using Both SIO Converter and Isolated PIO Terminal Block
- 3.5 Specifications of I/O Signals
- 3.6 I/O Signals for PIO Pattern 1 [3 Points] (Air Cylinder)
- 3.7 I/O Signals for PIO Pattern 0 [8 Points]
- 3.8 I/O Signals for PIO Pattern 2 [16 Points] (Setting by Zone BoundaryParameters)
- 3.9 I/O Signals for PIO Pattern 3 [16 Points] (Setting in Zone Fields in thePosition Table)
- 3.10 Emergency-Stop Circuit
- 3.11 Extension Cable
- 4. Electrical Specifications
- 5. Data Entry
- 6. Operation in the “3 Points (Air Cylinder)” Mode
- 7. Operation in the “8 Points” and “16 Points” Modes
- 7.1 How to Start
- 7.2 Position Table and Parameter Settings Required for Operation
- 7.3 How to Execute Home Return
- 7.4 Home Return and Movement after Start (16 Points)
- 7.5 Positioning Mode (Back and Forth Movement between Two Points)
- 7.6 Push & Hold Mode
- 7.7 Speed Change during Movement
- 7.8 Operation at Different Acceleration and Deceleration Settings
- 7.9 Pause
- 7.10 Zone Signal
- 7.11 Incremental Moves
- 7.12 Notes on Incremental Mode
- 8. Parameter Settings
- 9. Troubleshooting
- 10. Maintenance and Inspection
- 11. Appendix
- Change History

166
11. Appendix
152
Appendix
* Appendix
Example of Basic ERC2 Positioning Sequence
Given below is an example of basic sequence for creating a positioning sequence using the ERC2.
indicates PIO signals of the ERC2 controller.
Home return signal
HOME
HOME PEND
HEND
HOME
HEND
A
A
B
A
B
C
D
H
I
J
K
L
A C
D
C
C
I
H K
H
I
J
J PEND L
K
J PEND
L
Home return
request
Home return request
Positioning
start request
to position 1
Positioning
start request
to position 1
The positioning start request signal is converted to pulse in such a
way that one start signal is issued for one positioning operation.
Auxiliary start signal
for next positioning
({)
Check if positioning to the specified position has completed.
Positioning start pulse
to position 1
A
uxiliary positioning start
pulse to position 1
A
uxiliary positioning
start for position 1
Start check for position 1
Completion of positioning to
position 1
B
11.1.7 ERC2-RGD6C
51.7
23.720
159
134
114
ST
M.E.
2
ST
58.3
13
54
54
20
145
114
54
53
52
42
30
F
34
F
10
ST
3.3558
4-M5
8-M5
50 100 150 200 250 300
Guide Weight [kg]
Weight of Guide
Main Unit [kg]
0.4
2.0
0.4
2.1
0.5
2.3
0.6
2.6
0.6
2.7
0.7
2.9
Stroke
Home
ME : Mechanical End
11.1.8 ERC2-RGD7C
ST 62 ST
61
4
170
145
125
12.5
64
64
F
12
F
36
ST
3.557.5103022
158
125
65
63
62
52
34
25
4-M6
8-M6
M.E.
50 100 150 200 250 300
0.5
3.2
0.6
3.5
0.7
3.7
0.8
4.0
0.9
4.2
1.0
4.5
Stroke
Home
ME : Mechanical End
Guide Weight [kg]
Weight of Guide
Main Unit [kg]