Manual

73
[Function] This command moves the actuator to the designated position number from point to point without
interpolation.
[Example] MOVP 100
Moves to Position No. 100 (point to point).
MOVP *1
If variable 1 is 150, then the actuator moves to
position number 150 (point to point).
Each axis moves at its
own designated speed.
noisnapxE
noitidnoc
)RO·DNA(
tupnI
noitidnoc
)galF·O/I(
dnammoC
tsoP
)galF·troptuptuO(
dnammoC 1dnarepO 2dnarepO
lanoitpOlanoitpOPVOM.onnoitisoPlanoitpO
noitisoP
.oN
123
1
2
3
001
-0.001
0
-0.001
0
-x.xxx
x
051
-0.002
0
-0.002
0
-x.xxx
x
Move path when X-axis moves to 200mm point and Y-axis moves
to 100mm point from home.
X axis
Y axis motion complete
Y axis
100mm
200mm
Home 0
12. SEL Language
MOVP (Point to-Point Position Data)
MOVD (Direct Designate Move)
noisnapxE
noitidnoc
)RO·DNA(
tupnI
noitidnoc
)galF·O/I(
dnammoC
tsoP
)galF·troptuptuO(
dnammoC 1dnarepO 2dnarepO
lanoitpOlanoitpODVOMnoitisopevoMlanoitpO
[Function] Moves the actuator to a position designated in operand 1.
Output turns OFF when axis move starts, and upon completion, turns ON.
[Example 1] MOVD 100 Move the axis to position 100.
[Example 2] LET 1 100 Assign 100 to variable 1.
MOVD *1 Move the axis to variable 1 (content 100) position.
* Note: This command is applicable to the DS type only.