Owner's manual

AppendixError List (MAIN application) (In the panel window, the
three digits after “E” indicate an error number.)
428
Appendix
(In the panel window, the three digits after “E” indicate an error number.)
Error No. Error name Description, action, etc.
D58 Fieldbus error (INIT timeout) An INIT timeout was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D59 Fieldbus error (DPRAM write/read) A DPRAM write/read error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D5A Fieldbus error (TOGGLE timeout) A TOGGLE timeout was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D5B Fieldbus error (Access-privilege retry over) An access-privilege retry over error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D5C Fieldbus error (Access-privilege open error) An access-privilege open error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D5D Fieldbus error (FBRS link error) A FBRS link error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D5E Fieldbus error (Mailbox response) A mailbox response error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D67 Motor/encoder configuration information mismatch error The “motor/encoder configuration information” (motor identification number and
encoder identification number) in driver parameter No. 26 does not match the
“motor/ encoder configuration information” (motor identification number and
encoder identification number) in encoder parameter No. 11. Check the
parameter values, encoder cable connection, etc.
D68 No remote-mode control support board error Hardware supporting remote-mode control is not installed, although remote-mode
control (AUTO/MANU) is specified in I/O parameter No. 79.
D69 External terminal block overcurrent or power-supply error Overcurrent or power-supply error in the external terminal block
D70 Option use permission error Check if any option whose use is not permitted is specified in the system
program.
D6A Hardware unsupported function error An attempt was made to use a function not supported by the hardware.
D6B Overrun error The overrun sensor was actuated.