AppendixError List (MAIN application) (In the panel window, the
three digits after “E” indicate an error number.)
424
Appendix
(In the panel window, the three digits after “E” indicate an error number.)
Error No. Error name Description, action, etc.
CAA Palletizing PASE/PAPS non-declaration error Neither PASE nor PAPS palletizing-setting command is set. Set either command.
CAB Palletizing position number error The specified palletizing position number is invalid.
CAC Palletizing position number setting over The specified palletizing position number exceeds the position number range
calculated for the current palletizing setting.
CAD Palletizing PX/PY/PZ-axis duplication error Any two of the specified PX, PY and PZ-axes for palletizing are the same axis.
CAE Insufficient valid axes for palletizing 3-point teaching data There are not enough valid axes in the point data for palletizing 3-point teaching.
Axes to comprise the palletizing PX/PY planes cannot be specified.
CAF Excessive valid axes for palletizing 3-point teaching data There are too many valid axes in the point data for palletizing 3-point teaching.
Axes to comprise the palletizing PX/PY planes cannot be specified.
CB0 Mismatched valid axes for palletizing 3-point teaching data The valid axis pattern in the point data for palletizing 3-point teaching does not
match.
CB1 Offset setting error at palletizing 3-point teaching Zigzag offset (not zero) cannot be set in palletizing 3-point teaching, if the
reference point is the same as the end point of the PX-axis.
CB2 BGPA/EDPA pair-end mismatch error The BGPA/EDPA syntax is invalid. EDPA was declared before BGPA, or another
BGPA was declared after BGPA without first declaring EDPA.
CB4 Arch-motion Z-axis non-declaration error Z-axis has not been declared by PCHZ or ACHZ.
CB5 BGPA non-declaration error during palletizing setting Palletizing setting cannot be performed without first declaring BGPA. Declare
BGPA.
CB6 Palletizing point error The palletizing points are invalid (non-Z-axis components for arch-motion
movement are absent, etc.).
CB7 Arch-trigger non-declaration error Declare arch triggers using PTRG or ATRG.
CB8 No 3-point teaching setting error at palletizing angle acquisition The palletizing angle cannot be acquired until setting by palletizing 3-point
teaching is complete.
CB9 PX/PY-axis indeterminable error at palletizing angle acquisition Angle cannot be calculated because there are too many valid axes in the 3-point
teaching data and thus PX/PY-axes cannot be specified.
CBA Reference-axis/PY/PY-axis mismatch error at palletizing angle
acquisition
Angle cannot be calculated because the reference axis for angle calculation is
neither of the axes comprising the PX/PY-axes as set by 3-point teaching.
CBB Reference-point/PX-axis end-point duplication error at palletizing
angle acquisition
Angle cannot be calculated because the reference point of 3-point teaching is the
same as the PX-axis end-point data other than the PZ-axis component and thus
arc tangent cannot be calculated.
CBC Palletizing motion calculation error Trapezoid control calculation error for palletizing motion
CBD MOD command divisor 0 error “0” was specified as the divisor in the MOD command.
CBE Target-locus boundary over error The target position or movement locus exceeded the positioning boundary in the
infinite-stroke mode.