Appendix
Axis-Specific Parameters
No Parameter name
Default value
(Reference)
Input range Unit Remarks
84 Maximum
synchronization
correction speed of
synchro slave axis
5 0 ~ 100 mm/sec Maximum travel speed for synchronization position
correction of slave axis. Valid only with a synchro slave axis.
* Note: Not limited by the safety speed.
85 Home-return
acceleration/
deceleration
15 1 ~ 300 0.01 G
86 Zone 1 MAX 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
87 Zone 1 MIN 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
88 Zone 1 output number 0 0 ~ 899 Physical output port or global flag (Output is invalid if “0” is
input; multiple specification is invalid)
89 Zone 2 MAX 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
90 Zone 2 MIN 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
91 Zone 2 output number 0 0 ~ 899 Physical output port or global flag (Output is invalid if “0” is
input; multiple specification is invalid)
92 Zone 3 MAX 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
93 Zone 3 MIN 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
94 Zone 3 output number 0 0 ~ 899 Physical output port or global flag (Output is invalid if “0” is
input; multiple specification is invalid)
95 Zone 4 MAX 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
96 Zone 4 MIN 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
97 Zone 4 output number 0 0 ~ 899 Physical output port or global flag (Output is invalid if “0” is
input; multiple specification is invalid)
98 For future expansion 0 Reference
only
99 For future expansion 0 Reference
only
100 ~
118
(For expansion) 0 ~
119 FSG 0 0 ~ 100
120 FFF 10 0 ~ 100 * Change is prohibited unless instructed by the manufacturer.
121~
170
(For expansion) 0 ~
171 0 ~
172 0 ~
173 0 ~
174 0 ~
175 0 ~
176 0 ~
~ 200 (For expansion) 0 ~