User Manual
¾ The quality of coaxial cable will reduce or increase the transmission distance. The EOC-100Kit is tested for use
with RG-59U 75 Ohm copper based 20AWG coaxial cable.
¾ That is free from damage as in cuts, breaks, or cracks to the outer covering and insulated shielding which may
compromise the signal conductivity of the cable.
¾ For safety, DO NOT put EOC signals in the same conduit as high-voltage wiring.
For more specific information regarding wire types, gauges, and proper installation techniques, please call Tech
Support at 886-3-5103001 or email to support@i-view.com.tw
Installation Steps:
1. Connect the unit's RJ45 Ethernet jack to the IP camera using a standard Cat5 or Cat6 patch cable and unit's BNC
socket to a 75 ohm coax cable with BNC connector.
2. Plug the DC 12V power adapter to the EOC-100V Ethernet over Coax extender.
3. Connect the unit's (Which on the HUB site) BNC socket to a 75 ohm coax cable with BNC connector, then plug
the a standard Cat5 or Cat6 patch cable to the unit’s RJ45 Ethernet jack to the Switching HUB.
4. In order to get better transmission distance, the Ethernet patch cable should be a standard Cat5 or Cat6 cable and
less than 2 meters
.
Troubleshooting:
The following table describes some of the symptoms, probable causes and possible solutions
Problem Possible Cause
Hub LED indicator is
OK, but no video
9 Check IP camera and unit device connections.
9 Check coax cable condition and BNC connectors is 75 Ohm.
9 Check cable that cable distances do not exceed EOC-110V operating distance.
9 Check the built in jumper cable of IP camera used non- standard Cat. 5 cables.
9 Check that the camera is powered.
Network lost
9 Check network switch termination(s) & link status.
9 Check network routing table(s).
9 Confer with site Network Administrator.
Specification:
Phone: 886-3-510-3001 Fax: 886-3-510-3002
Mail: sales@i-view.com.tw
Item \Model EOC-100V EOC-110V
Ethernet
Connector: RJ-45
Speed: 10/100Base-T full-duplex
Coaxial
Connector: BNC 75 Ohm
Cable: Any 75 Ohm coax cable
Distance: 300 meters (Typ.)@ full rate via RG59U coax cable
Bandwidth: 100M bits/Second
Power Consumption
DC 12V / 50mA None
Dimension /Weight
100 x 55 x 34 mm / 140g 55 x 25 x 25 mm / 60g
Environment
Operation: 0℃to 50℃; 20% ~ 85% non-condensing