Certificates
IA Number: MTEx-S/20.0012 X
Rev.0
Page 2 of 3
Template: MTExDOC101 Rev 5
Approve date :(2019/06/11)
This certification indicates compliance with R10.1 of the Mines Health and Safety Act and/or EMR 8(1) of the
Occupational Health and Safety Act, provided that the apparatus is used as prescribed in accordance with:
1) Any conditions set out in this Certificate;
2) This certificate only covers equipment imported between the “Issued” and “Expiry” dates;
3) When the supporting Q.A.N. (Quality Assurance Notification) of the equipment manufacturer expires,
it is the responsibility of the applicant (as mentioned above) to submit a valid Q.A.N to MTEx
Laboratories.
4) The test results presented in this Ex Test Report relate only to the item or product tested.
1. OVERVIEW
Equipment and systems covered by this Certificate are as follows:
The IS930.1 is the intrinsically safe and rugged industrial tablet for use in explosion
hazardous areas of Zone 1 and Zone 21. The IS930.1 provides numerous technologies like
4G (LTE), NFC, GPS, Wi-Fi and Bluetooth LE. Equipped with an Android operating system,
amplified loudspeaker and option keys, which allows the allocation of user specific
functions or applications
2. ELECTRICAL/ AND SAFETY PARAMETERS
Supply:
The tablet IS930.1 has a fixed installed rechargeable Li-Ion battery Uo = 3.8 V (Uo_max =
4.2 V).
Interfaces:
The opening of the interface covers in explosive atmospheres is not permitted.
Wired data connection and charging is only allowed outside ex-hazardous areas.
Um = 5.88 V, this is ensured by using the Docking Station DS930.1, the i.safe
PROTECTOR cables or other accessories specified by i.safe MOBILE GmbH.
A commercially available SD card may be used in the corresponding slot in the hazardous
area. The internal electrical capacity of the SD card is negligible.
3. REASON FOR REVIEW
ARP 0108: 2014 Requirement.
4. DOCUMENTATION PROVIDED
IECEx Quality Assessment Report (DE/EPS/QAR12.0003/07)
IECEx Certificate of Conformity (IECEx EPS 19.0034 X)
5. SPECIAL CONDITIONS OF USE (X)
The battery may be charged outside explosion hazardous areas only.
The device must be protected against permanent UV light emission and high electrostatic
charge processes.
The permitted ambient temperature range is -20°C to +60°C.