Certificates
Megaton Systems (Pty) Ltd
T
/
A
MTEx Laboratories
Unit 1 Wierda Place, 17 Hilda Avenue, Centurion.
Postnet #89
Privatebag X1028
Dorinkloof
0140
Reg No.: 2012/055110/07; VAT No.: 4830273027
Tel : +27 12 030 1034 (MTEx Offices)
Fax mail: 086 416 6760
E- mail: info@mtexlab.co.za
Website: www.mtexlab.co.za
Page 1 of 3
Template: MTExDOC101 Rev 5
Approve date :(2019/06/11)
ACCREDITED TEST LABORATORY
IN TERMS OF THE ARP 0108: “REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS”
INSPECTION AUTHORITY CERTIFICATE
i.safe MOBILE GmbH. Issued: 2020/01/30
i_Park Tauberfranken 10 Expire: 2023/01/30
97922 Lauda-Koenigshofen Revision: 0
Germany
Equipment: Intrinsically safe industrial tablet.
Manufacturer: i.safe MOBILE GmbH
Address: i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen
Model/Type: IS930.1
Serial No.: All units imported between Issued and Expiry dates.
Applicant:
i.safe MOBILE GmbH
Inspection Authority Number: MTEx-S/20.0012 X
MTEx Record Number: MTEx 0901/20.0012
Ex Rating: Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db IP6X
Standards used:
SANS 60079
-
0: 2019 Ed.6
IEC 60079-0: 2017 Ed.7
Explosive atmospheres – Part 0: General requirements.
SANS 60079
-
11: 2012 Ed.4
IEC 60079-11: 2011 Ed.6
Explosive atmospheres
–
Part 11: Equipment protection by
intrinsic safety "i".
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in
the Standards listed above.
Hazardous Area: Zone 1, 2, 21 and 22
Occurrence: Intermittent and abnormal conditions
Hazardous Group: IIC/IIIC
Permitted Temperature: T4 (135°C) and 135°C for dust applications
Equipment Protection level (EPL):
EPL
Definition
Gas Dust
Gb Db
Equipment for explosive gas and dust atmospheres, having a "high" level of protection, which
is not a source of ignition in normal operation or during expected malfunctions.
Gc Dc
Equipment for explosive gas and dust atmospheres, having an "enhanced" level of
protection, which is not a source of ignition in normal operation and which may have some
additional protection to ensure that it remains inactive as an ignition source in the case of
regular expected occurrences (for example failure of a lamp).