Certificates

IA Number: MTEx-M/20.0014 X
Rev.0
Page 2 of 3
Template: MTExDOC101 Rev 5
Approve date :(2019/06/11)
Equipment Protection level (EPL):
EPL
Definition
Gas Dust
Ma
Equipment for installation in a mine susceptible to firedamp, having a "very high" level of
protection, which has sufficient security that it is unlikely to become an ignition source in
normal operation, during expected malfunctions or during rare malfunctions, even when left
energized in the presence of an outbreak of gas.
Mb
Equipment for installation in a mine susceptible to firedamp, having a "high" level of
protection, which has sufficient security that it is unlikely to become a source of ignition in
normal operation or during expected malfunctions in the time span between there being an
outbreak of gas and the equipment being de-energized.
This certification indicates compliance with R10.1 of the Mines Health and Safety Act and/or EMR 8(1) of the
Occupational Health and Safety Act, provided that the apparatus is used as prescribed in accordance with:
1) Any conditions set out in this Certificate;
2) This certificate only covers equipment imported between the “Issued” and “Expiry” dates;
3) When the supporting Q.A.N. (Quality Assurance Notification) of the equipment manufacturer expires,
it is the responsibility of the applicant (as mentioned above) to submit a valid Q.A.N to MTEx
Laboratories.
4) The test results presented in this Ex Test Report relate only to the item or product tested.
1. OVERVIEW
Equipment and systems covered by this Certificate are as follows:
The intrinsically safe and rugged, industrial tablet IS930.M1 has been designed for use in
mines susceptible to firedamp. The IS930.M1 provides numerous technologies like 4G
(LTE), NFC, GPS, Wi-Fi and Bluetooth LE. Equipped with an Android operating system,
amplified loudspeaker and option keys, which allows the allocation of user specific
functions or applications.
2. ELECTRICAL/ AND SAFETY PARAMETERS
Supply: The tablet IS930.M1 has a fixed installed rechargeable Li-Ion battery Uo = 3.8 V
(Uo_max = 4.2 V).
Interfaces: The opening of the interface covers in explosive atmospheres is not permitted.
Wired data connection and charging is only allowed outside ex-hazardous areas.
Um = 5.88 V, this is ensured by using the Docking Station DS930.1, the i.safe
PROTECTOR cables or other accessories specified by i.safe MOBILE GmbH. A list of
approved accessories can be found at www.isafe-mobile.com.
A commercially available SD card may be used in the corresponding slot in the hazardous
area. The internal electrical capacity of the SD card is negligible
3. REASON FOR REVIEW
ARP 0108: 2014 Requirement.