Instructions / Assembly

28.
EN
5.8: Impeller Cleaning
Impeller cleaning is important when storing the water pump for a
long period of time, as well as considered good practice during
regular maintenance checks.
1. Fill up the pump with fresh water through the primer opening.
2. Start the pump and let it run for 5 to 8 minutes or until water
evaporates upon contact with the engine block.
3. Drain the water through the pump drain outlet.
4. Flush the pump with clean water pouring it through the primer
opening.
5. Drive the drain screw back on.
5.9: Transportation
pump drain outletWater drain screw
WARNING
Contact with a hot engine or exhaust system can cause
serious burns or fires. Let the engine cool down before
transporting the unit.