User Manual
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 5571 4 C E High Pressure Common Rail Fuel
Pressure Relief Valve - Voltage be-
low normal, or shorted to low source
ECM 5571 4 C L High Pressure Common Rail Fuel
Pressure Relief Valve - Voltage be-
low normal, or shorted to low source
ECM 5571 11 C E High Pressure Common Rail Fuel
Pressure Relief Valve - Root Cause
Not Known
ECM 5571 11 C L High Pressure Common Rail Fuel
Pressure Relief Valve - Root Cause
Not Known
ECM 5571 31 C E High Pressure Common Rail Fuel
Pressure Relief Valve - Condition Ex-
ists
ECM 5571 31 C L High Pressure Common Rail Fuel
Pressure Relief Valve - Condition Ex-
ists
ECM 5576 14 P E Aftertreatment #1 Identification :
Special Instruction
ECM 5576 14 P L Aftertreatment #1 Identification :
Special Instruction
ECM 5576 2 P E Aftertreatment #1 Identification : Er-
ratic, Intermittent, or Incorrect
ECM 5576 2 P L Aftertreatment #1 Identification : Er-
ratic, Intermittent, or Incorrect
ECM 5576 8 P E Aftertreatment #1 Identification : Ab-
normal Frequency, Pulse Width, or
Perod
ECM 5576 8 P L Aftertreatment #1 Identification : Ab-
normal Frequency, Pulse Width, or
Perod
ECM 558 13 C F Voltage detected at idle validation
on-idle circuit when voltage at throttle
position circuit indicates the pedal is
not at idle or voltage detected at idle
validation off-idle circuit when volt-
age at throttle position circuit indi-
cates the pedal is at rest.
ECM
558 19 C F Accelerator Pedal or Lever Idle Vali-
dation Switch - Received Network
Data In Error
ECM 558 9 C F Accelerator Pedal or Lever Idle Vali-
dation Switch - Abnormal update rate
ECM 558 13 C E Accelerator Pedal or Lever Idle Vali-
dation Switch Circuit - Out of Calibra-
tion
ECM 558 13 C L Accelerator Pedal or Lever Idle Vali-
dation Switch Circuit - Out of Calibra-
tion
ECM 558 19 C E Accelerator Pedal or Lever Idle Vali-
dation Switch - Received Network
Data In Error
ECM 558 19 C L Accelerator Pedal or Lever Idle Vali-
dation Switch - Received Network
Data In Error
ECM 558 2 C E Accelerator Pedal or Lever Idle Vali-
dation Switch - Data erratic, intermit-
tent or incorrect
ECM 558 2 C L Accelerator Pedal or Lever Idle Vali-
dation Switch - Data erratic, intermit-
tent or incorrect
ECM 558 2 P E Accelerator Pedal 1 Low Idle Switch :
Erratic, Intermittent, or Incorrect
ECM 558 2 P L Accelerator Pedal 1 Low Idle Switch :
Erratic, Intermittent, or Incorrect
ECM 558 2 S E Low idle switch error state from coor-
dinator
ECM 558 2 S L Low idle switch error state from coor-
dinator
ECM 558 9 C E Accelerator Pedal or Lever Idle Vali-
dation Switch - Abnormal update rate
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 558 9 C L Accelerator Pedal or Lever Idle Vali-
dation Switch - Abnormal update rate
ECM 558 2 C F Accelerator Pedal or Lever Idle Vali-
dation Circuit - Data Erratic, Intermit-
tent, or Incorrect
ECM 558 4 C F Accelerator Pedal or Lever Idle Vali-
dation Circuit - Voltage Below Nor-
mal, or Shorted to Low Source
ECM 558 4 C E Accelerator Pedal or Lever Idle Vali-
dation Circuit- Voltage Below Nor-
mal, or Shorted to Low Source
ECM 558 4 C L Accelerator Pedal or Lever Idle Vali-
dation Circuit- Voltage Below Nor-
mal, or Shorted to Low Source
MCU 558 0 * E Differential Lock Pressure-Data Valid
But Above Normal Operational
Range
MCU 558 0 * L Differential Lock Pressure-Data Valid
But Above Normal Operational
Range
MCU 558 1 * E Differential Lock Pressure-Data Valid
But Below Normal Operational
Range
MCU 558 1 * L Differential Lock Pressure-Data Valid
But Below Normal Operational
Range
MCU 558 4 * E Differential Lock Pressure-Voltage
Below Normal, Or Shorted To Low
Source
MCU 558 4 * L Differential Lock Pressure-Voltage
Below Normal, Or Shorted To Low
Source
ECM 558 2 S F Low idle switch error state from coor-
dinator
MCU 558 0 * F Differential Lock Pressure Sensor
Data Above Normal Range (or Open
Circuit)
MCU 558 1 * F Differential Lock Pressure Sensor
Data Below Normal Range
MCU 558 2 * E Differential Lock Pressure-Data Er-
ratic, Intermittent Or Incorrect
MCU 558 2 * F Differential Lock Pressure Sensor
Data Error
MCU 558 2 * L Differential Lock Pressure-Data Er-
ratic, Intermittent Or Incorrect
MCU 558 4 * F Differential Lock Pressure Sensor
Circuit - Voltage Below Normal, or
Shorted to Low Source
ECM 5585 18 C F Engine Injector Metering Rail 1
Cranking Pressure - Data Valid But
Below Normal Operating Range - Mo
ECM 5585 18 C E Engine Injector Metering Rail 1
Cranking Pressure - Data Valid But
Below Normal Operating Range - Mo
ECM 5585 18 C L Engine Injector Metering Rail 1
Cranking Pressure - Data Valid But
Below Normal Operating Range - Mo
ECM 5588 14 P E Propretary Network #2 : Special In-
struction
ECM 5588 14 P L Propretary Network #2 : Special In-
struction
ECM 559 10 S F Accelerator pedal/kick down switch,
EMS and coordinator do not agree
ECM 559 10 S E Accelerator pedal/kick down switch,
EMS and coordinator do not agree
ECM 559 2 S F Kickdown signal defect via CAN
ECM 559 10 S L Accelerator pedal/kick down switch,
EMS and coordinator do not agree
ECM 559 2 S E Kickdown signal defect via CAN
ECM 559 9 S F Accelerator pedal kickdown CAN
message, faulty
continued..........