User Manual

...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
erating Range - Moderately Severe Lev-
el
ECM 4360 16 C L Aftertreatment 1 SCR Intake Tempera-
ture - Data Valid But Above Normal Op-
erating Range - Moderately Severe Lev-
el
ECM 4360 16 P E Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : High - moderate se-
verity (2)
ECM 4360 16 P L Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : High - moderate se-
verity (2)
ECM 4360 18 P E Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : Low - moderate se-
verity (2)
ECM 4360 18 P L Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : Low - moderate se-
verity (2)
ECM 4360 3 C E Aftertreatment 1 SCR Intake Tempera-
ture Sensor Circuit - Voltage above nor-
mal, or shorted to high source
ECM 4360 3 C L Aftertreatment 1 SCR Intake Tempera-
ture Sensor Circuit - Voltage above nor-
mal, or shorted to high source
ECM 4360 3 P E Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : Voltage Above Nor-
mal
ECM 4360 3 P L Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : Voltage Above Nor-
mal
ECM 4360 4 C E Aftertreatment 1 SCR Intake Tempera-
ture Sensor Circuit - Voltage below nor-
mal, or shorted to low source
ECM 4360 4 C L Aftertreatment 1 SCR Intake Tempera-
ture Sensor Circuit - Voltage below nor-
mal, or shorted to low source
ECM 4360 4 P E Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : Voltage Below Nor-
mal
ECM 4360 4 P L Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : Voltage Below Nor-
mal
ECM 4360 15 C E Aftertreatment 1 SCR Intake Tempera-
ture - Data Valid But Above Normal Op-
erating Range - Least Severe
ECM 4360 15 C L Aftertreatment 1 SCR Intake Tempera-
ture - Data Valid But Above Normal Op-
erating Range - Least Severe
ECM 4360 17 P E Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : Low - least severe
(1)
ECM 4360 17 P L Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : Low - least severe
(1)
ECM 4360 2 C E Aftertreatment 1 SCR Intake Tempera-
ture Sensor - Data erratic, intermittent or
incorrect
ECM 4360 2 C L Aftertreatment 1 SCR Intake Tempera-
ture Sensor - Data erratic, intermittent or
incorrect
ECM 4360 20 P E Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : Data Drifted High
ECM 4360 20 P L Aftertreatment #1 SCR Catalyst Intake
Gas Temperature : Data Drifted High
ECM 4363 0 C E Aftertreatment 1 SCR Outlet Tempera-
ture - Data valid but above normal op-
erational range - Most Severe
ECM 4363 0 C L Aftertreatment 1 SCR Outlet Tempera-
ture - Data valid but above normal op-
erational range - Most Severe
ECM 4363 0 C F Aftertreatment 1 SCR Outlet Tempera-
ture - Data valid but above normal op-
erational range - Most Severe
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 4363 16 C F Aftertreatment 1 SCR Outlet Tempera-
ture - Data Valid But Above Normal Op-
erating Range - Moderately Severe Lev-
el
ECM 4363 16 C E Aftertreatment 1 SCR Outlet Tempera-
ture - Data Valid But Above Normal Op-
erating Range - Moderately Severe Lev-
el
ECM 4363 16 C L Aftertreatment 1 SCR Outlet Tempera-
ture - Data Valid But Above Normal Op-
erating Range - Moderately Severe Lev-
el
ECM 4363 2 C F Aftertreatment 1 SCR Outlet Tempera-
ture Sensor - Data erratic, intermittent or
incorrect
ECM 4363 3 C F Aftertreatment 1 SCR Outlet Tempera-
ture Sensor Circuit - Voltage above nor-
mal, or shorted to high source
ECM 4363 4 C F Aftertreatment 1 SCR Outlet Tempera-
ture Sensor Circuit - Voltage below nor-
mal, or shorted to low source
ECM 4363 3 C E Aftertreatment 1 SCR Outlet Tempera-
ture Sensor Circuit - Voltage above nor-
mal, or shorted to high source
ECM 4363 3 C L Aftertreatment 1 SCR Outlet Tempera-
ture Sensor Circuit - Voltage above nor-
mal, or shorted to high source
ECM 4363 4 C E Aftertreatment 1 SCR Outlet Tempera-
ture Sensor Circuit - Voltage below nor-
mal, or shorted to low source
ECM 4363 4 C L Aftertreatment 1 SCR Outlet Tempera-
ture Sensor Circuit - Voltage below nor-
mal, or shorted to low source
ECM 4363 2 C E Aftertreatment 1 SCR Outlet Tempera-
ture Sensor - Data erratic, intermittent or
incorrect
ECM 4363 2 C L Aftertreatment 1 SCR Outlet Tempera-
ture Sensor - Data erratic, intermittent or
incorrect
ECM 4364 18 C F Aftertreatment SCR Catalyst Conversion
Efficiency - Data Valid But Below Normal
Operating Range - Moderately Severe
Level
ECM 4364 18 C E Aftertreatment SCR Catalyst Conversion
Efficiency - Data Valid But Below Normal
Operating Range - Moderately Severe
Level
ECM 4364 18 C L Aftertreatment SCR Catalyst Conversion
Efficiency - Data Valid But Below Normal
Operating Range - Moderately Severe
Level
ECM 4364 18 P E Aftertreatment #1 SCR Catalyst Conver-
sion Efficiecy : Low - moderate severity
(2)
ECM 4364 18 P L Aftertreatment #1 SCR Catalyst Conver-
sion Efficiecy : Low - moderate severity
(2)
ECM 4364 31 C E Aftertreatment 1 SCR Conversion Effi-
ciency - Condition Exists
ECM 4364 31 C L Aftertreatment 1 SCR Conversion Effi-
ciency - Condition Exists
ECM 4364 17 C E Aftertreatment SCR Catalyst Conversion
Efficiency - Data Valid But Below Normal
Operating Range - Moderately Severe
Level
ECM 4364 17 C L Aftertreatment SCR Catalyst Conversion
Efficiency - Data Valid But Below Normal
Operating Range - Moderately Severe
Level
ECM 4364 2 P E Aftertreatment #1 SCR Catalyst Conver-
sion Efficiecy : Erratic, Intermittent ,or In-
corrcet
ECM 4364 2 P L Aftertreatment #1 SCR Catalyst Conver-
sion Efficiecy : Erratic, Intermittent ,or In-
corrcet
continued..........
73
5 SPN 4~