TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 4343 6 S F Reductant hose fault
ECM 4344 3 C F Aftertreatment Diesel Exhaust Fluid Line
Heater 3 Circuit - Voltage above normal,
or shorted to high source
ECM 4344 4 C F Aftertreatment Diesel Exhaust Fluid Line
Heater 3 Circuit - Voltage below normal,
or shorted to low source
ECM 4344 5 C F Aftertreatment Diesel Exhaust Fluid Line
Heater 3 Circuit - Current below normal
or open circuit
ECM 4344 3 C E Aftertreatment Diesel Exhaust Fluid Line
Heater 3 Circuit - Voltage above normal,
or shorted to high source
ECM 4344 3 C L Aftertreatment Diesel Exhaust Fluid Line
Heater 3 Circuit - Voltage above normal,
or shorted to high source
ECM 4344 4 C E Aftertreatment Diesel Exhaust Fluid Line
Heater 3 Circuit - Voltage below normal,
or shorted to low source
ECM 4344 4 C L Aftertreatment Diesel Exhaust Fluid Line
Heater 3 Circuit - Voltage below normal,
or shorted to low source
ECM 4344 5 C E Aftertreatment Diesel Exhaust Fluid Line
Heater 3 Circuit - Current below normal
or open circuit
ECM 4344 5 C L Aftertreatment Diesel Exhaust Fluid Line
Heater 3 Circuit - Current below normal
or open circuit
ECM 4345 2 S E Fault in the reductant heater for reduc-
tant hose 3 (H27).
ECM 4345 2 S L Fault in the reductant heater for reduc-
tant hose 3 (H27).
ECM 4345 3 S E Fault in the reductant heater for reduc-
tant hose 3 (H27).
ECM 4345 3 S L Fault in the reductant heater for reduc-
tant hose 3 (H27).
ECM 4345 4 S E Fault in the reductant heater for reduc-
tant hose 3 (H27).
ECM 4345 4 S L Fault in the reductant heater for reduc-
tant hose 3 (H27).
ECM 4345 5 S E Fault in the reductant heater for reduc-
tant hose 3 (H27).
ECM 4345 5 S L Fault in the reductant heater for reduc-
tant hose 3 (H27).
ECM 4345 6 S E The reductant heater for reductant hose
3 (H27) has consumed more power than
permitted.
ECM 4345 6 S L The reductant heater for reductant hose
3 (H27) has consumed more power than
permitted.
ECM 4345 2 S F Reductant hose fault
ECM 4345 3 S F Reductant hose fault
ECM 4345 4 S F Reductant hose fault
ECM 4345 5 S F Reductant hose fault
ECM 4345 6 S F Reductant hose fault
ECM 4347 2 S E Electrical fault in the reductant heater for
reductant hose 4 (H28).
ECM 4347 2 S L Electrical fault in the reductant heater for
reductant hose 4 (H28).
ECM 4347 3 S E Fault in the reductant heater for reduc-
tant hose 4 (H28).
ECM 4347 3 S L Fault in the reductant heater for reduc-
tant hose 4 (H28).
ECM 4347 4 S E Fault in the reductant heater for reduc-
tant hose 4 (H28).
ECM 4347 4 S L Fault in the reductant heater for reduc-
tant hose 4 (H28).
ECM 4347 5 S E Fault in the reductant heater for reduc-
tant hose 4 (H28).
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 4347 5 S L Fault in the reductant heater for reduc-
tant hose 4 (H28).
ECM 4347 6 S E The reductant heater for reductant hose
4 (H28) has consumed more power than
permitted.
ECM 4347 6 S L The reductant heater for reductant hose
4 (H28) has consumed more power than
permitted.
ECM 4347 2 S F Reductant heater fault
ECM 4347 3 S F Reductant heater fault
ECM 4347 4 S F Reductant heater fault
ECM 4347 5 S F Reductant heater fault
ECM 4347 6 S F Reductant heater fault
ECM 4353 31 C E Aftertreatment 1 Diesel Exhaust Fluid
Doser Heating Mode Request - Condi-
tion Exists
ECM 4353 31 C L Aftertreatment 1 Diesel Exhaust Fluid
Doser Heating Mode Request - Condi-
tion Exists
ECM 4354 5 P E Aftertreatment #1 DEF Line Heater #1 :
Current Below Normal
ECM 4354 5 P L Aftertreatment #1 DEF Line Heater #1 :
Current Below Normal
ECM 4354 6 P E Aftertreatment #1 DEF Line Heater #1 :
Current Above Normal
ECM 4354 6 P L Aftertreatment #1 DEF Line Heater #1 :
Current Above Normal
ECM 4355 5 P E Aftertreatment #1 DEF Line Heater #2 :
Current Below Normal
ECM 4355 5 P L Aftertreatment #1 DEF Line Heater #2 :
Current Below Normal
ECM 4355 6 P E Aftertreatment #1 DEF Line Heater #2 :
Current Above Normal
ECM 4355 6 P L Aftertreatment #1 DEF Line Heater #2 :
Current Above Normal
ECM 4356 5 P E Aftertreatment #1 DEF Line Heater #3 :
Current Below Normal
ECM 4356 5 P L Aftertreatment #1 DEF Line Heater #3 :
Current Below Normal
ECM 4356 6 P E Aftertreatment #1 DEF Line Heater #3 :
Current Above Normal
ECM 4356 6 P L Aftertreatment #1 DEF Line Heater #3 :
Current Above Normal
ECM 4360 0 C E Aftertreatment 1 SCR Intake Tempera-
ture - Data valid but above normal op-
erational range - Most Severe Level
ECM 4360 0 C L Aftertreatment 1 SCR Intake Tempera-
ture - Data valid but above normal op-
erational range - Most Severe Level
ECM 4360 0 C F Aftertreatment 1 SCR Intake Tempera-
ture - Data valid but above normal op-
erational range - Most Severe Level
ECM 4360 16 C F Aftertreatment 1 SCR Intake Tempera-
ture - Data Valid But Above Normal Op-
erating Range - Moderately Severe Lev-
el
ECM 4360 15 C F Aftertreatment 1 SCR Intake Tempera-
ture - Data Valid But Above Normal Op-
erating Range - Least Severe
ECM 4360 2 C F Aftertreatment 1 SCR Intake Tempera-
ture Sensor - Data erratic, intermittent or
incorrect
ECM 4360 3 C F Aftertreatment 1 SCR Intake Tempera-
ture Sensor Circuit - Voltage above nor-
mal, or shorted to high source
ECM 4360 4 C F Aftertreatment 1 SCR Intake Tempera-
ture Sensor Circuit - Voltage below nor-
mal, or shorted to low source
ECM 4360 16 C E Aftertreatment 1 SCR Intake Tempera-
ture - Data Valid But Above Normal Op-