User Manual

...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
perature sensor or by the engine coolant
temperature sensor.
ECM 412 15 C F Exhaust Gas Recirculation (EGR) tem-
perature - Data Valid but Above Normal
Operating Range, Least Severe Level.
ECM 412 16 C F EGR Temperature - Data Valid But
Above Normal Operating Range, Moder-
ately Severe Level.
ECM 412 2 C F Exhaust Gas Recirculation Temperature
- Data erratic, intermittent or incorrect
ECM 412 15 C E Exhaust Gas Recirculation Temperature
- Data Valid But Above Normal Operat-
ing Range - Least Severe Level
ECM 412 15 C L Exhaust Gas Recirculation Temperature
- Data Valid But Above Normal Operat-
ing Range - Least Severe Level
ECM 412 15 P E Exhaust Gas Recirculation Tempera-
ture : High - least severe(1)
ECM 412 15 P L Exhaust Gas Recirculation Tempera-
ture : High - least severe(1)
ECM 412 16 C E Exhaust Gas Recirculation Temperature
- Data Valid But Above Normal Operat-
ing Range - Moderately Severe Level
ECM 412 16 C L Exhaust Gas Recirculation Temperature
- Data Valid But Above Normal Operat-
ing Range - Moderately Severe Level
ECM 412 16 P E Exhaust Gas Recirculation Tempera-
ture : High - moderate severity (2)
ECM 412 16 P L Exhaust Gas Recirculation Tempera-
ture : High - moderate severity (2)
ECM 412 2 C E Exhaust Gas Recirculation Temperature
- Data erratic, intermittent or incorrect
ECM 412 2 C L Exhaust Gas Recirculation Temperature
- Data erratic, intermittent or incorrect
ECM 412 3 C E Exhaust Gas Recirculation Temperature
Sensor Circuit - Voltage above normal,
or shorted to high source
ECM 412 3 C L Exhaust Gas Recirculation Temperature
Sensor Circuit - Voltage above normal,
or shorted to high source
ECM 412 3 P E Exhaust Gas Recirculation Differential
Pressure -Out of Calibration
ECM 412 3 P L Exhaust Gas Recirculation Differential
Pressure -Out of Calibration
ECM 412 3 Y E EGR gas temperature sensor error (volt-
age high)
ECM 412 3 Y L EGR gas temperature sensor error (volt-
age high)
ECM 412 4 C E Exhaust Gas Recirculation Temperature
Sensor Circuit - Voltage below normal,
or shorted to low source
ECM 412 4 C L Exhaust Gas Recirculation Temperature
Sensor Circuit - Voltage below normal,
or shorted to low source
ECM 412 4 P E Exhaust Gas Recirculation Temperature
- Voltage below normal
ECM 412 4 P L Exhaust Gas Recirculation Temperature
- Voltage below normal
ECM 412 4 Y E EGR gas temperature sensor error (volt-
age low)
ECM 412 4 Y L EGR gas temperature sensor error (volt-
age low)
ECM 412 3 C F Exhaust Gas Recirculation Tempera-
ture : Exhaust Gas Recirculation Tem-
perature Sensor Circuit - Voltage Above
Normal, or Shorted to High Source
ECM 412 4 C F Exhaust Gas Recirculation Tempera-
ture : Exhaust Gas Recirculation Tem-
perature Sensor Circuit - Voltage Below
Normal, or Shorted to Low Source
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 4182 4 C F Generator Output Frequency Adjust Po-
tentiometer Circuit - Voltage below nor-
mal, or shorted to low source
ECM 4182 4 C E Generator Output Frequency Adjust Po-
tentiometer Circuit - Voltage below nor-
mal, or shorted to low source
ECM 4182 4 C L Generator Output Frequency Adjust Po-
tentiometer Circuit - Voltage below nor-
mal, or shorted to low source
ECM 4183 4 C F Droop Adjust Potentiometer Circuit -
Voltage below normal, or shorted to low
source
ECM 4183 4 C E Droop Adjust Potentiometer Circuit -
Voltage below normal, or shorted to low
source
ECM 4183 4 C L Droop Adjust Potentiometer Circuit -
Voltage below normal, or shorted to low
source
ECM 4184 4 C F Gain Adjust Potentiometer Circuit - Volt-
age below normal, or shorted to low
source
ECM 4184 4 C E Gain Adjust Potentiometer Circuit - Volt-
age below normal, or shorted to low
source
ECM 4184 4 C L Gain Adjust Potentiometer Circuit - Volt-
age below normal, or shorted to low
source
ECM 4185 31 C F Overspeed Shutdown Relay Driver Diag-
nostic has detected an error - Condition
Exists
ECM 4185 31 C E Overspeed Shutdown Relay Driver Diag-
nostic has detected an error - Condition
Exists
ECM 4185 31 C L Overspeed Shutdown Relay Driver Diag-
nostic has detected an error - Condition
Exists
ECM 4186 31 C E Low Oil Pressure (LOP) Shutdown Relay
Driver Diagnostic has detected an error -
Condition Exists
ECM 4186 31 C L Low Oil Pressure (LOP) Shutdown Relay
Driver Diagnostic has detected an error -
Condition Exists
ECM 4187 31 C F High Engine Temperature (HET) Shut-
down Relay Driver Diagnostic has detec-
ted an error - Condition Exists
ECM 4187 31 C E High Engine Temperature (HET) Shut-
down Relay Driver Diagnostic has detec-
ted an error - Condition Exists
ECM 4187 31 C L High Engine Temperature (HET) Shut-
down Relay Driver Diagnostic has detec-
ted an error - Condition Exists
ECM 4188 31 C F Pre-Low Oil Pressure Warning Relay
Driver Diagnostic has detected an error -
Condition Exists
ECM 4188 31 C E Pre-Low Oil Pressure Warning Relay
Driver Diagnostic has detected an error -
Condition Exists
ECM 4188 31 C L Pre-Low Oil Pressure Warning Relay
Driver Diagnostic has detected an error -
Condition Exists
TCU 42 * * E Fuel level sensor circuit is shorted to
ground
ECM 4201 10 S E Engine position sensor 1, position diff
ECM 4201 10 S L Engine position sensor 1, position diff
ECM 4201 2 S E Engine position sensor 1, faulty
ECM 4201 2 S L Engine position sensor 1, faulty
ECM 4201 7 S E Engine position sensor 1, faulty
ECM 4201 7 S L Engine position sensor 1, faulty
ECM 4201 10 S F Engine position sensor 1, position diff
ECM 4201 2 S F Engine position sensor 1, faulty
continued..........