User Manual

...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 3490 7 C F Aftertreatment Purge Air Actuator -
Mechanical system not responding
or out of adjustment
ECM 3490 3 C E Aftertreatment Purge Air Actuator
Circuit - Voltage above normal, or
shorted to high source
ECM 3490 3 C L Aftertreatment Purge Air Actuator
Circuit - Voltage above normal, or
shorted to high source
ECM 3490 4 C E Aftertreatment Purge Air Actuator
Circuit - Voltage below normal, or
shorted to low source
ECM 3490 4 C L Aftertreatment Purge Air Actuator
Circuit - Voltage below normal, or
shorted to low source
ECM 3490 7 C E Aftertreatment Purge Air Actuator -
Mechanical system not responding
or out of adjustment
ECM 3490 7 C L Aftertreatment Purge Air Actuator -
Mechanical system not responding
or out of adjustment
TCU 35 * * E Controller input voltage is over 38V
TCU 35 * * L S.C. TO GROUND AT TURBINE
SPEED INPUT
TCU 35 * * F S.C. TO GROUND AT TURBINE
SPEED INPUT
ECM 3509 3 C F Sensor Supply Voltage #1 Circuit
Voltage Above Normal, or Shorted
to High Source
ECM 3509 4 C F Sensor Supply Voltage #1 Circuit
Voltage Below Normal, or Shorted to
Low Source
ECM 3509 2 P E Sensor Supply Voltage 1 : Erratic,
Intermittent, or Incorrect
ECM 3509 2 P L Sensor Supply Voltage 1 : Erratic,
Intermittent, or Incorrect
ECM 3509 3 C E Sensor Supply 1 Circuit - Voltage
above normal, or shorted to high
source
ECM 3509 3 C L Sensor Supply 1 Circuit - Voltage
above normal, or shorted to high
source
ECM 3509 3 P E Sensor Supply Voltage 1 : Voltage
Above Normal
ECM 3509 3 P L Sensor Supply Voltage 1 : Voltage
Above Normal
ECM 3509 4 C E Sensor Supply 1 Circuit - Voltage
below normal, or shorted to low
source
ECM 3509 4 C L Sensor Supply 1 Circuit - Voltage
below normal, or shorted to low
source
ECM 3509 4 P E Sensor Supply Voltage 1 : Voltage
Below Normal
ECM 3509 4 P L Sensor Supply Voltage 1 : Voltage
Below Normal
ECM 3510 3 C F Sensor Supply Voltage #2 Circuit
Voltage Above Normal, or Shorted
to High Source
ECM 3510 4 C F Sensor Supply Voltage #2 Circuit
Voltage Below Normal, or Shorted to
Low Source
ECM 3510 2 P E Sensor Supply Voltage 2 : Erratic,
Intermittent, or Incorrect
ECM 3510 2 P L Sensor Supply Voltage 2 : Erratic,
Intermittent, or Incorrect
ECM 3510 3 C E Sensor Supply 2 Circuit - Voltage
above normal, or shorted to high
source
ECM 3510 3 C L Sensor Supply 2 Circuit - Voltage
above normal, or shorted to high
source
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 3510 3 P E Sensor Supply Voltage 2 : Voltage
Above Normal
ECM 3510 3 P L Sensor Supply Voltage 2 : Voltage
Above Normal
ECM 3510 4 C E Sensor Supply 2 Circuit - Voltage
below normal, or shorted to low
source
ECM 3510 4 C L Sensor Supply 2 Circuit - Voltage
below normal, or shorted to low
source
ECM 3510 4 P E Sensor Supply Voltage 2 : Voltage
Below Normal
ECM 3510 4 P L Sensor Supply Voltage 2 : Voltage
Below Normal
ECM 3511 3 C F Sensor Supply Voltage #3 Circuit -
Voltage Above Normal, or Shorted
to High Source
ECM 3511 4 C F Sensor Supply Voltage #3 Circuit
Voltage Below Normal, or Shorted to
Low Source
ECM 3511 2 P E Sensor Supply Voltage 3 : Erratic,
Intermittent, or Incorrect
ECM 3511 2 P L Sensor Supply Voltage 3 : Erratic,
Intermittent, or Incorrect
ECM 3511 3 C E Sensor Supply 3 Circuit - Voltage
above normal, or shorted to high
source
ECM 3511 3 C L Sensor Supply 3 Circuit - Voltage
above normal, or shorted to high
source
ECM 3511 3 P E Sensor Supply Voltage 3 : Voltage
Above Normal
ECM 3511 3 P L Sensor Supply Voltage 3 : Voltage
Above Normal
ECM 3511 4 C E Sensor Supply 3 Circuit - Voltage
below normal, or shorted to low
source
ECM 3511 4 C L Sensor Supply 3 Circuit - Voltage
below normal, or shorted to low
source
ECM 3511 4 P E Sensor Supply Voltage 3 : Voltage
Below Normal
ECM 3511 4 P L Sensor Supply Voltage 3 : Voltage
Below Normal
ECM 3512 3 C F Sensor Supply Voltage #4 Circuit
Voltage Above Normal, or Shorted
to High Source
ECM 3512 4 C F Sensor Supply Voltage #4 Circuit
Voltage Below Normal, or Shorted to
Low Source
ECM 3512 3 C E Sensor Supply 4 Circuit - Voltage
above normal, or shorted to high
source
ECM 3512 3 C L Sensor Supply 4 Circuit - Voltage
above normal, or shorted to high
source
ECM 3512 3 P E Sensor Supply Voltage 4 : Voltage
Above Normal
ECM 3512 3 P L Sensor Supply Voltage 4 : Voltage
Above Normal
ECM 3512 4 C E Sensor Supply 4 Circuit - Voltage
below normal, or shorted to low
source
ECM 3512 4 C L Sensor Supply 4 Circuit - Voltage
below normal, or shorted to low
source
ECM 3512 4 P E Sensor Supply Voltage 4 : Voltage
Below Normal
ECM 3512 4 P L Sensor Supply Voltage 4 : Voltage
Below Normal
continued..........
61
4 SPN 3~