User Manual

...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
in the valve block for exhaust gas af-
tertreatment V184.
ECM 3480 8 S E The air pressure is too high when
the air control valve in the valve
block for exhaust gas aftertreatment
is open.
ECM 3480 8 S L The air pressure is too high when
the air control valve in the valve
block for exhaust gas aftertreatment
is open.
ECM 3480 9 S E The air pressure in the valve block
for exhaust gas aftertreatment is not
increasing even though the air con-
trol valve is open.
ECM 3480 9 S L The air pressure in the valve block
for exhaust gas aftertreatment is not
increasing even though the air con-
trol valve is open.
ECM 3480 10 S F Reductant circuit pressure
ECM 3480 2 S F Fault in doser valve
ECM 3480 3 S F Fault in dose valve sensor
ECM 3480 4 S F Fault in dose valve sensor
ECM 3480 8 S F Reductant circuit pressure
ECM 3480 9 S F Reductant circuit pressure
ECM 3481 16 C F Aftertreatment Fuel Rate - Data Val-
id But Above Normal Operating
Range - Moderately Severe Level
ECM 3481 16 C E Aftertreatment Fuel Rate - Data Val-
id But Above Normal Operating
Range - Moderately Severe Level
ECM 3481 16 C L Aftertreatment Fuel Rate - Data Val-
id But Above Normal Operating
Range - Moderately Severe Level
ECM 3482 13 C F Aftertreatment Fuel Shutoff Valve
Swapped - Out of Calibration
ECM 3482 16 C F Aftertreatment Fuel Shutoff Valve -
Data Valid But Above Normal Oper-
ating Range - Moderately Severe
ECM 3482 2 C F Aftertreatment Fuel Shutoff Valve -
Data erratic, intermittent or incorrect
ECM 3482 3 C F Aftertreatment Fuel Shutoff Valve
Circuit - Voltage above normal, or
shorted to high source
ECM 3482 4 C F Aftertreatment Fuel Shutoff Valve
Circuit - Voltage below normal, or
shorted to low source
ECM 3482 7 C F Aftertreatment Fuel Shutoff Valve -
Mechanical system not responding
or out of adjustment
ECM 3482 13 C E Aftertreatment Fuel Shutoff Valve
Swapped - Out of Calibration
ECM 3482 13 C L Aftertreatment Fuel Shutoff Valve
Swapped - Out of Calibration
ECM 3482 16 C E Aftertreatment Fuel Shutoff Valve -
Data Valid But Above Normal Oper-
ating Range - Moderately Severe
ECM 3482 16 C L Aftertreatment Fuel Shutoff Valve -
Data Valid But Above Normal Oper-
ating Range - Moderately Severe
ECM 3482 2 C E Aftertreatment Fuel Shutoff Valve -
Data erratic, intermittent or incorrect
ECM 3482 2 C L Aftertreatment Fuel Shutoff Valve -
Data erratic, intermittent or incorrect
ECM 3482 3 C E Aftertreatment Fuel Shutoff Valve
Circuit - Voltage above normal, or
shorted to high source
ECM 3482 3 C L Aftertreatment Fuel Shutoff Valve
Circuit - Voltage above normal, or
shorted to high source
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 3482 4 C E Aftertreatment Fuel Shutoff Valve
Circuit - Voltage below normal, or
shorted to low source
ECM 3482 4 C L Aftertreatment Fuel Shutoff Valve
Circuit - Voltage below normal, or
shorted to low source
ECM 3482 7 C E Aftertreatment Fuel Shutoff Valve -
Mechanical system not responding
or out of adjustment
ECM 3482 7 C L Aftertreatment Fuel Shutoff Valve -
Mechanical system not responding
or out of adjustment
ECM 3485 2 S E SCR main unit, air pressure sensor
after orifice circuit supply
ECM 3485 2 S L SCR main unit, air pressure sensor
after orifice circuit supply
ECM 3485 3 S E SCR main unit, air pressure sensor
after orifice circuit high
ECM 3485 3 S L SCR main unit, air pressure sensor
after orifice circuit high
ECM 3485 4 S E SCR main unit, air pressure sensor
after orifice circuit low
ECM 3485 4 S L SCR main unit, air pressure sensor
after orifice circuit low
ECM 3485 7 S E SCR, air circuit blocked
ECM 3485 7 S L SCR, air circuit blocked
ECM 3485 1 S F SCR main unit, air pressure too low
ECM 3485 1 S E SCR main unit, air pressure too low
ECM 3485 18 S F EEC, air supply low
ECM 3485 1 S L SCR main unit, air pressure too low
ECM 3485 2 S F SCR main unit, air pressure sensor
after orifice circuit supply
ECM 3485 18 S E EEC, air supply low
ECM 3485 20 S F SCR main unit, air pressure sensor
after orifice plausible error
ECM 3485 18 S L EEC, air supply low
ECM 3485 3 S F SCR main unit, air pressure sensor
after orifice circuit high
ECM 3485 4 S F SCR main unit, air pressure sensor
after orifice circuit low
ECM 3485 7 S F SCR, air circuit blocked
ECM 3485 20 S E SCR main unit, air pressure sensor
after orifice plausible error
ECM 3485 9 S F SCR main unit, air pressure sensor
after orifice performance
ECM 3485 20 S L SCR main unit, air pressure sensor
after orifice plausible error
ECM 3485 9 S E SCR main unit, air pressure sensor
after orifice performance
ECM 3485 9 S L SCR main unit, air pressure sensor
after orifice performance
ECM 3489 3 C F Aftertreatment #1 Air Enable Actua-
tor Voltage Above Normal, or Shor-
ted to High Source. High signal volt-
age has been detected at the cata-
lyst air solenoid circuit.
ECM 3489 4 C F Aftertreatment #1 Air Enable Actua-
tor Voltage Below Normal, or Shor-
ted to Low Source. Low signal volt-
age has been detected at the cata-
lyst air solenoid circuit.
ECM 3490 3 C F Aftertreatment Purge Air Actuator
Circuit - Voltage above normal, or
shorted to high source
ECM 3490 4 C F Aftertreatment Purge Air Actuator
Circuit - Voltage below normal, or
shorted to low source
continued..........