TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 3361 2 S F Reductant doser injection valve
ECM 3361 2 C L Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit Temperature - Data
erratic, intermittent or incorrect
ECM 3361 3 S F SCR reductant dosing valve, short
circuit to battery
ECM 3361 4 S F Reductant doser injection valve
ECM 3361 5 S F SCR reductant dosing valve, open
circuit
ECM 3361 6 S F Reductant doser injection valve
ECM 3361 2 S E Fault in reductant doser injection
valve.
ECM 3361 2 S L Fault in reductant doser injection
valve.
ECM 3362 31 C F Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit Input Lines - Condi-
tion Exists
ECM 3362 0 S E The reductant pressure has been
above the permitted level.
ECM 3362 0 S L The reductant pressure has been
above the permitted level.
ECM 3362 1 S E Required reductant pressure cannot
be reached.
ECM 3362 1 S L Required reductant pressure cannot
be reached.
ECM 3362 2 S E SCR reductant pressure, error
ECM 3362 2 S L SCR reductant pressure, error
ECM 3362 0 S F Reductant pressure
ECM 3362 1 S F Reductant pressure
ECM 3362 2 S F SCR reductant pressure, error
ECM 3362 31 C E Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit Input Lines - Condi-
tion Exists
ECM 3362 31 C L Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit Input Lines - Condi-
tion Exists
ECM 3363 16 C F Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Data Valid But
Above Normal Operating Range -
Moderately Severe Level
ECM 3363 18 C F Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Data Valid But Be-
low Normal Operating Range - Mod-
erately Severe Level
ECM 3363 3 C F Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Voltage above nor-
mal, or shorted to high source
ECM 3363 4 C F Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Voltage below nor-
mal, or shorted to low source
ECM 3363 7 C F Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Mechanical system
not responding or out of adjustment
ECM 3363 0 S E SCR main unit, reductant heater, cir-
cuit high
ECM 3363 0 S L SCR main unit, reductant heater, cir-
cuit high
ECM 3363 16 C E Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Data Valid But
Above Normal Operating Range -
Moderately Severe Level
ECM 3363 16 C L Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Data Valid But
Above Normal Operating Range -
Moderately Severe Level
ECM 3363 16 S E SCR main unit, high temperature
high limit exceeded
ECM 3363 16 S L SCR main unit, high temperature
high limit exceeded
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 3363 17 S E SCR reductant tank temperatur too
low
ECM 3363 17 S L SCR reductant tank temperatur too
low
ECM 3363 18 C E Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Data Valid But Be-
low Normal Operating Range - Mod-
erately Severe Level
ECM 3363 18 C L Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Data Valid But Be-
low Normal Operating Range - Mod-
erately Severe Level
ECM 3363 18 S E SCR main unit, low temperature limit
exceeded
ECM 3363 18 S L SCR main unit, low temperature limit
exceeded
ECM 3363 2 S E SCR main unit, reductant heater,
open load
ECM 3363 2 S L SCR main unit, reductant heater,
open load
ECM 3363 3 C E Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Voltage above nor-
mal, or shorted to high source
ECM 3363 3 C L Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Voltage above nor-
mal, or shorted to high source
ECM 3363 3 S E SCR main unit, internal heating
pump, short circuit to battery
ECM 3363 3 S L SCR main unit, internal heating
pump, short circuit to battery
ECM 3363 4 C E Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Voltage below nor-
mal, or shorted to low source
ECM 3363 4 C L Aftertreatment 1 Diesel Exhaust Flu-
id Tank Heater - Voltage below nor-
mal, or shorted to low source
ECM 3363 4 S E SCR main unit, reductant tempera-
ture sensor circuit low
ECM 3363 4 S L SCR main unit, reductant tempera-
ture sensor circuit low
ECM 3363 5 P E Aftertreatment #1 DEF Tank Heat-
er : Current Below Normal
ECM 3363 5 P L Aftertreatment #1 DEF Tank Heat-
er : Current Below Normal
ECM 3363 5 S E SCR main unit, internal heating
pump, open load
ECM 3363 5 S L SCR main unit, internal heating
pump, open load
ECM 3363 6 P E Aftertreatment #1 DEF Tank Heat-
er : Current Above Normal
ECM 3363 6 P L Aftertreatment #1 DEF Tank Heat-
er : Current Above Normal
ECM 3363 6 S E The heater of the reductant doser
has consumed more power than
permitted.
ECM 3363 6 S L The heater of the reductant doser
has consumed more power than
permitted.
ECM 3363 8 S E SCR main unit, reductant heater, cir-
cuit performance
ECM 3363 8 S L SCR main unit, reductant heater, cir-
cuit performance
ECM 3363 0 S F SCR main unit, reductant heater, cir-
cuit high
ECM 3363 15 S F SCR reagent tank temperature too
high
ECM 3363 16 S F SCR main unit, high temperature
high limit exceeded
ECM 3363 17 S F SCR reductant tank temperatur too
low
continued..........