User Manual
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 3360 16 S L SCR main unit, internal supply volt-
age high
ECM 3360 19 S E SCR main unit, communication error
ECM 3360 19 S L SCR main unit, communication error
ECM 3360 3 P E Aftertreatment #1 DEF Controller :
Voltage Above Normal
ECM 3360 3 P L Aftertreatment #1 DEF Controller :
Voltage Above Normal
ECM 3360 3 S E SCR main unit, ventilation valve
test, short to battery
ECM 3360 3 S L SCR main unit, ventilation valve
test, short to battery
ECM 3360 5 S E SCR main unit, ventilation valve
test, open load
ECM 3360 5 S L SCR main unit, ventilation valve
test, open load
ECM 3360 6 S E SCR main unit, system voltage error
ECM 3360 6 S L SCR main unit, system voltage error
ECM 3360 9 P E Aftertreatment #1 DEF Controller :
Abnormal Update Rate
ECM 3360 9 P L Aftertreatment #1 DEF Controller :
Abnormal Update Rate
ECM 3360 9 S E EEC3 has demanded SCR Major
functional failure reductant dosing
stopped actions
ECM 3360 9 S L EEC3 has demanded SCR Major
functional failure reductant dosing
stopped actions
ECM 3360 0 S F SCR system adaptation have
reached max values
ECM 3360 1 S F SCR system adaptation have
reached min values
ECM 3360 10 S F EEC3 System has demanded "SCR
minor functional failure" actions
ECM 3360 12 S F SCR main unit, error
ECM 3360 16 S F SCR main unit, internal supply volt-
age high
ECM 3360 19 S F SCR main unit, communication error
ECM 3360 12 S E SCR main unit, error
ECM 3360 2 S F EEC3 System has demanded "SCR
Hazardous major functional failure"
actions
ECM 3360 12 S L SCR main unit, error
ECM 3360 3 S F SCR main unit, ventilation valve
test, short to battery
ECM 3360 2 S E EEC3 System has demanded SCR
Hazardous major functional failure
actions
ECM 3360 2 S L EEC3 System has demanded SCR
Hazardous major functional failure
actions
ECM 3360 4 P E Aftertreatment #1 DEF Controller :
Voltage Below Normal
ECM 3360 4 S F SCR main unit, internal supply volt-
age low
ECM 3360 4 P L Aftertreatment #1 DEF Controller :
Voltage Below Normal
ECM 3360 5 S F SCR main unit, ventilation valve
test, open load
ECM 3360 4 S E SCR main unit, internal supply volt-
age low
ECM 3360 7 S F SCR main unit, ignition switch plau-
sible error
ECM 3360 4 S L SCR main unit, internal supply volt-
age low
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 3360 9 S F EEC3 has demanded "SCR Major
functional failure reductant dosing
stopped" actions
ECM 3360 7 S E SCR main unit, ignition switch plau-
sible error
ECM 3360 7 S L SCR main unit, ignition switch plau-
sible error
ECM 3361 1 C F
ECM 3361 12 C F Catalyst Dosing Control Unit Bad In-
telligent Device or Component. An
internal error has been detected in
the catalyst dosing control unit.
ECM 3361 2 C F Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit Temperature - Data
erratic, intermittent or incorrect
ECM 3361 3 C F Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit - Voltage above nor-
mal, or shorted to high source
ECM 3361 4 C F Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit - Voltage below nor-
mal, or shorted to low source
ECM 3361 9 C F Dosing Control Unit Data Link Ab-
normal Update Rate. Data Link com-
munications between the ECM and
the Dosing Control Unit have been
interrupted.
ECM 3361 3 C E Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit - Voltage above nor-
mal, or shorted to high source
ECM 3361 3 C L Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit - Voltage above nor-
mal, or shorted to high source
ECM 3361 3 S E SCR reductant dosing valve, short
circuit to battery
ECM 3361 3 S L SCR reductant dosing valve, short
circuit to battery
ECM 3361 4 C E Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit - Voltage below nor-
mal, or shorted to low source
ECM 3361 4 C L Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit - Voltage below nor-
mal, or shorted to low source
ECM 3361 4 S E Fault in reductant doser injection
valve.
ECM 3361 4 S L Fault in reductant doser injection
valve.
ECM 3361 5 P E Aftertreatment #1 DEF Dosing Unit :
Current Below Normal
ECM 3361 5 P L Aftertreatment #1 DEF Dosing Unit :
Current Below Normal
ECM 3361 5 S E SCR reductant dosing valve, open
circuit
ECM 3361 5 S L SCR reductant dosing valve, open
circuit
ECM 3361 6 P E Aftertreatment #1 DEF Dosing Unit :
Current Above Normal
ECM 3361 6 P L Aftertreatment #1 DEF Dosing Unit :
Current Above Normal
ECM 3361 6 S E Fault in reductant doser injection
valve.
ECM 3361 6 S L Fault in reductant doser injection
valve.
ECM 3361 10 S F SCR main unit, reductant pressure
not plausible
ECM 3361 10 S E SCR main unit, reductant pressure
not plausible
ECM 3361 10 S L SCR main unit, reductant pressure
not plausible
ECM 3361 2 C E Aftertreatment 1 Diesel Exhaust Flu-
id Dosing Unit Temperature - Data
erratic, intermittent or incorrect
continued..........
55
4 SPN 3~