User Manual
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
MCU 221 6 * L ATT Relief Setting EPPR 1 Valve-Cur-
rent Above Normal Or Grounded Cir-
cuit
MCU 222 5 * E ATT Relief Setting EPPR 2 Valve-Volt-
age Below Normal, Or Shorted To
Low Source
MCU 222 5 * L ATT Relief Setting EPPR 2 Valve-Volt-
age Below Normal, Or Shorted To
Low Source
MCU 222 6 * E ATT Relief Setting EPPR 2 Valve-Cur-
rent Above Normal Or Grounded Cir-
cuit
MCU 222 6 * L ATT Relief Setting EPPR 2 Valve-Cur-
rent Above Normal Or Grounded Cir-
cuit
TCU 23 * * L S.C. TO BATTERY VOLTAGE AT
LOAD SENSOR INPUT
TCU 23 * * F S.C. TO BATTERY VOLTAGE AT
LOAD SENSOR INPUT
EH-
CU
2304 5 * L Boom Up EPPR Valve Input Current
Below Normal or Open Circuit
EH-
CU
2304 6 * L Boom Up EPPR Valve Input Current
Above Normal or Grounded Circuit
EH-
CU
2304 0 * L Boom Up EPPR Valve Input Value
Above Normal Operation Range
EH-
CU
2304 1 * L Boom Up EPPR Valve Input Value Be-
low Normal Operation Range
EH-
CU
2304 14 * L Boom Up EPPR Valve Block Parame-
ter Invalid
EH-
CU
2305 5 * L Boom Down EPPR Valve Input Cur-
rent Below Normal or Open Circuit
EH-
CU
2305 6 * L Boom Down EPPR Valve Input Cur-
rent Above Normal or Grounded Cir-
cuit
EH-
CU
2305 0 * L Boom Down EPPR Valve Input Value
Above Normal Operation Range
EH-
CU
2305 1 * L Boom Down EPPR Valve Input Value
Below Normal Operation Range
EH-
CU
2305 14 * L Boom Down EPPR Valve Block Pa-
rameter Invalid
EH-
CU
2306 5 * L Bucket In EPPR Valve Input Current
Below Normal or Open Circuit
EH-
CU
2306 6 * L Bucket In EPPR Valve Input Current
Above Normal or Grounded Circuit
EH-
CU
2306 0 * L Bucket In EPPR Valve Input Value
Above Normal Operation Range
EH-
CU
2306 1 * L Bucket In EPPR Valve Input Value Be-
low Normal Operation Range
EH-
CU
2306 14 * L Bucket In EPPR Valve Block Parame-
ter Invalid
EH-
CU
2307 5 * L Bucket Dump EPPR Valve Input Cur-
rent Below Normal or Open Circuit
EH-
CU
2307 6 * L Bucket Dump EPPR Valve Input Cur-
rent Above Normal or Grounded Cir-
cuit
EH-
CU
2307 0 * L Bucket Dump EPPR Valve Input Value
Above Normal Operation Range
EH-
CU
2307 1 * L Bucket Dump EPPR Valve Input Value
Below Normal Operation Range
EH-
CU
2307 14 * L Bucket Dump EPPR Valve Block Pa-
rameter Invalid
EH-
CU
2308 0 * L Aux. Up EPPR Valve Input Value
Above Normal Operation Range
EH-
CU
2308 1 * L Aux. Up EPPR Valve Input Value Be-
low Normal Operation Range
EH-
CU
2308 14 * L Aux. Up EPPR Valve Block Parameter
Invalid
EH-
CU
2308 5 * L Aux. Up EPPR Valve Input Current
Below Normal or Open Circuit
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
EH-
CU
2308 6 * L Aux. Up EPPR Valve Input Current
Above Normal or Grounded Circuit
EH-
CU
2309 0 * L Aux. Down EPPR Valve Input Data
Above Normal Operation Range
EH-
CU
2309 1 * L Aux. Down EPPR Valve Input Data
Below Normal Operation Range
EH-
CU
2309 14 * L Aux. Down EPPR Valve Block Param-
eter Invalid
EH-
CU
2309 5 * L Aux. Down EPPR Valve Input Current
Below Normal or Open Circuit
EH-
CU
2309 6 * L Aux. Down EPPR Valve Input Current
Above Normal or Grounded Circuit
EH-
CU
2311 0 * L Boom Joystick Position Input Value
Above Normal Operation Range
EH-
CU
2311 1 * L Boom Joystick Position Input Value
Below Normal Operation Range
EH-
CU
2311 2 * L Boom Joystick Position Signal Error
EH-
CU
2311 3 * L Boom Joystick Position Input Voltage
Above Normal or Shorted to High
Source
EH-
CU
2311 4 * L Boom Joystick Position Input Voltage
Below Normal or Shorted to Low
Source
EH-
CU
2311 13 * L Boom Joystick Position Control Block
Out of Calibration
EH-
CU
2311 14 * L Boom Joystick Position Control Block
Parameter Invalid
EH-
CU
2311 31 * L Boom Joysitck Position Signal Redun-
dancy Lost
EH-
CU
2313 0 * L Bucket Joystick Position Input Value
Above Normal Operation Range
EH-
CU
2313 1 * L Bucket Joystick Position Input Value
Below Normal Operation Range
EH-
CU
2313 2 * L Bucket Joystick Position Signal Error
EH-
CU
2313 3 * L Bucket Joystick Position Input Voltage
Above Normal or Shorted to High
Source
EH-
CU
2313 4 * L Bucket Joystick Position Input Voltage
Below Normal or Shorted to Low
Source
EH-
CU
2313 13 * L Bucket Joystick Position Control Block
Out of Calibration
EH-
CU
2313 14 * L Bucket Joystick Position Control Block
Parameter Invalid
EH-
CU
2313 31 * L Bucket Joysitck Position Signal Re-
dundancy Lost
EH-
CU
2315 0 * L Aux Joystick Position Input Value
Above Normal Operation Range
EH-
CU
2315 1 * L Aux Joystick Position Input Value Be-
low Normal Operation Range
EH-
CU
2315 13 * L Aux Joystick Position Control Block
Out of Calibration
EH-
CU
2315 14 * L Aux Joystick Position Control Block
Parameter Invalid
EH-
CU
2315 2 * L Aux Joystick Position Signal Error
EH-
CU
2315 3 * L Aux Joystick Position Input Voltage
Above Normal or Shorted to High
Source
EH-
CU
2315 31 * L Aux Joysitck Position Signal Redun-
dancy Lost
EH-
CU
2315 4 * L Aux Joystick Position Input Voltage
Below Normal or Shorted to Low
Source
EH-
CU
2317 9 * L Communication Timeout between EH-
CU and Steering Joystick
continued..........
37
3 SPN 2~