User Manual

...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 176
1
17 S E The level of reductant in the reduc-
tant tank is low.
ECM 176
1
19 S F Aftertreatment Diesel Exhaust Fluid
Tank Level
ECM 176
1
17 S L The level of reductant in the reduc-
tant tank is low.
ECM 176
1
2 S F Reductant tank level sensor, short
circuit to ground
ECM 176
1
3 S F Reductant tank level sensor, short
circuit to +24V
ECM 176
1
4 S F Aftertreatment Diesel Exhaust Fluid
Tank Level
ECM 176
1
5 S F Reductant tank level sensor, open
circuit
ECM 176
1
6 S F Aftertreatment Diesel Exhaust Fluid
Tank Level
ECM 176
1
8 S F Aftertreatment Diesel Exhaust Fluid
Tank Level
ECM 176
1
19 S E CAN communication to the reduc-
tant pick-up unit is interrupted.
ECM 176
1
19 S L CAN communication to the reduc-
tant pick-up unit is interrupted.
ECM 176
1
9 C E SAE J1939 Multiplexing PGN Time-
out Error - Abnormal update rate
ECM 176
1
9 C L SAE J1939 Multiplexing PGN Time-
out Error - Abnormal update rate
MCU 179 4 * E Breaker Operator Solenoid-Voltage
Below Normal, Or Shorted To Low
Source
MCU 179 4 * L Breaker Operator Solenoid-Voltage
Below Normal, Or Shorted To Low
Source
MCU 179 6 * E Breaker Operator Solenoid-Current
Above Normal Or Grounded Circuit
MCU 179 6 * L Breaker Operator Solenoid-Current
Above Normal Or Grounded Circuit
TCU 18 * * E Pump EPPR valve circuit is open or
shorted to ground
TCU 18 * * L S.C. TO BATTERY VOLTAGE AT
CUSTOMER SPECIFIC FUNCTION
NO. 1
TCU 18 * * F S.C. TO BATTERY VOLTAGE AT
CUSTOMER SPECIFIC FUNCTION
NO. 1
ECM 180
0
16 C E Battery Temperature - Data Valid
But Above Normal Operating Range
- Moderately Severe Level
ECM 180
0
16 C L Battery Temperature - Data Valid
But Above Normal Operating Range
- Moderately Severe Level
ECM 180
0
18 C E Battery Temperature - Data Valid
But Below Normal Operating Range
- Moderately Severe Level
ECM 180
0
18 C L Battery Temperature - Data Valid
But Below Normal Operating Range
- Moderately Severe Level
ECM 180
0
16 C F Battery Temperature : Battery Tem-
perature - Data Valid but Above
Normal Operational Range - Moder-
ately Severe Level
ECM 180
0
18 C F Battery Temperature : Battery Tem-
perature - Data Valid but Below Nor-
mal Operational Range - Moderately
Severe Level
MCU 181 4 * E Cooling Fan Reverse Solenoid-Volt-
age Below Normal, Or Shorted To
Low Source
MCU 181 4 * L Cooling Fan Reverse Solenoid-Volt-
age Below Normal, Or Shorted To
Low Source
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
MCU 181 6 * E Cooling Fan Reverse Solenoid-Cur-
rent Above Normal Or Grounded
Circuit
MCU 181 6 * L Cooling Fan Reverse Solenoid-Cur-
rent Above Normal Or Grounded
Circuit
MCU 181 4 * F Engine Cooling Fan Reverse Sole-
noid Circuit - Voltage Below Normal,
or Shorted to Low Source (or Open
Circuit)
MCU 181 6 * F Engine Cooling Fan Reverse Sole-
noid Circuit - Current Above Normal
ECM 181
8
31 C E Roll Over Protection Brake Control
Active - Condition Exists
ECM 181
8
31 C L Roll Over Protection Brake Control
Active - Condition Exists
ECM 181
8
31 C F Roll Over Protection Brake Control
Active - Condition Exists
MCU 183 4 * E Cooling Fan Reverse Driving Sta-
tus-Voltage Below Normal, Or Shor-
ted To Low Source
MCU 183 4 * L Cooling Fan Reverse Driving Sta-
tus-Voltage Below Normal, Or Shor-
ted To Low Source
MCU 183 6 * E Cooling Fan Reverse Driving Sta-
tus-Current Above Normal Or
Grounded Circuit
MCU 183 6 * L Cooling Fan Reverse Driving Sta-
tus-Current Above Normal Or
Grounded Circuit
MCU 183 4 * F Engine Cooling Fan Reverse Driv-
ing Status Signal Circuit - Voltage
Below Normal, or Shorted to Low
Source (or Open Circuit)
MCU 183 6 * F Engine Cooling Fan Reverse Driv-
ing Status Signal Circuit - Current
Above Normal
Warning 184 * * L (Warning) Steering Main Pump
Pressure Low
Warning 184 * * F (Warning) Steering Main Pump
Pressure Low
Warning 185 * * L (Warning) Emergency Steering Ac-
tive
Warning 185 * * F (Warning) Emergency Steering Ac-
tive
MCU 187 4 * E Emergency Steering Pump Relay-
Voltage Below Normal, Or Shorted
To Low Source
MCU 187 4 * L Emergency Steering Pump Relay-
Voltage Below Normal, Or Shorted
To Low Source
MCU 187 6 * E Emergency Steering Pump Relay-
Current Above Normal Or Grounded
Circuit
MCU 187 6 * L Emergency Steering Pump Relay-
Current Above Normal Or Grounded
Circuit
MCU 187 4 * F Emergency Steering Pump Relay
Circuit - Voltage Below Normal, or
Shorted to Low Source (or Open
Circuit)
MCU 187 6 * F Emergency Steering Pump Relay
Circuit . Current Above Normal
ECM 188 16 C F Engine Speed At Idle - Data Valid
But Above Normal Operating Range
- Moderately Severe Level
ECM 188 18 C F Engine Speed At Idle - Data Valid
But Below Normal Operating Range
- Moderately Severe Level
ECM 188 16 C E Engine Speed At Idle - Data Valid
But Above Normal Operating Range
- Moderately Severe Level
continued..........
32
2 SPN 1~