TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
ECM 138
7
3 C F Auxiliary Pressure Sensor Input # 2
Circuit – shorted high
ECM 138
7
4 C F Auxiliary Pressure Sensor Input # 2
Circuit – shorted low
ECM 138
8
14 C F Crankcase Pressure - Data Above
Normal Operational Range - Severe
Level.
ECM 138
8
14 C E Auxiliary Pressure Sensor Input 2 -
Special Instructions
ECM 138
8
14 C L Auxiliary Pressure Sensor Input 2 -
Special Instructions
ECM 138
8
3 C E Auxiliary Pressure Sensor Input 2
Circuit - Voltage above normal, or
shorted to high source
ECM 138
8
3 C L Auxiliary Pressure Sensor Input 2
Circuit - Voltage above normal, or
shorted to high source
ECM 138
8
4 C E Auxiliary Pressure Sensor Input 2
Circuit - Voltage below normal, or
shorted to low source
ECM 138
8
4 C L Auxiliary Pressure Sensor Input 2
Circuit - Voltage below normal, or
shorted to low source
ECM 138
8
3 C F Auxiliary Pressure : Auxiliary Pres-
sure Sensor Input # 2 Circuit - Volt-
age Above Normal, or Shorted to
High Source
ECM 138
8
4 C F Auxiliary Pressure : Auxiliary Pres-
sure Sensor Input # 2 Circuit - Volt-
age Below Normal, or Shorted to
Low Source
MCU 139 0 * E Option Pilot Pressure-Data Valid
But Above Normal Operational
Range
MCU 139 0 * L Option Pilot Pressure-Data Valid
But Above Normal Operational
Range
MCU 139 1 * E Option Pilot Pressure-Data Valid
But Below Normal Operational
Range
MCU 139 1 * L Option Pilot Pressure-Data Valid
But Below Normal Operational
Range
MCU 139 4 * E Option Pilot Pressure-Voltage Be-
low Normal, Or Shorted To Low
Source
MCU 139 4 * L Option Pilot Pressure-Voltage Be-
low Normal, Or Shorted To Low
Source
MCU 139 2 * E Option Pilot Pressure-Data Erratic,
Intermittent Or Incorrect
MCU 139 2 * L Option Pilot Pressure-Data Erratic,
Intermittent Or Incorrect
ECM 139
9
3 C F Auxiliary Pressure Sensor Input 1
Circuit - Voltage Above Normal, or
Shorted to High Source. High signal
voltage detected at the OEM pres-
sure circuit.
TCU 14 * * E P3 pressure sensor circuit is shorted
to power supply(24V) line
TCU 14 * * L LOGICAL ERROR AT PARKBRAKE
STATUS
TCU 14 * * F LOGICAL ERROR AT PARKBRAKE
STATUS
MCU 140 5 * E Main Pump EPPR Valve Current-
Current Below Normal Or Open Cir-
cuit
MCU 140 5 * L Main Pump EPPR Valve Current-
Current Below Normal Or Open Cir-
cuit
MCU 140 6 * E Main Pump EPPR Valve Current-
Current Above Normal Or Grounded
Circuit
continued..........
...........continued
TYPE SPN FMI
En-
gine
Ma-
chine
type
Description
MCU 140 6 * L Main Pump EPPR Valve Current-
Current Above Normal Or Grounded
Circuit
MCU 141 5 * E Boom Priority (Against Swing)
EPPR Valve Current -Current Below
Normal Or Open Circuit
MCU 141 5 * L Boom Priority (Against Swing)
EPPR Valve Current -Current Below
Normal Or Open Circuit
MCU 141 6 * E Boom Priority (Against Swing)
EPPR Valve Current -Current Above
Normal Or Grounded Circuit
MCU 141 6 * L Boom Priority (Against Swing)
EPPR Valve Current -Current Above
Normal Or Grounded Circuit
MCU 143 5 * E Travel EPPR Valve Current-Current
Below Normal Or Open Circuit
MCU 143 5 * L Travel EPPR Valve Current-Current
Below Normal Or Open Circuit
MCU 143 6 * E Travel EPPR Valve Current-Current
Above Normal Or Grounded Circuit
MCU 143 6 * L Travel EPPR Valve Current-Current
Above Normal Or Grounded Circuit
MCU 144 5 * E Attachment Flow Valve Current-Cur-
rent Below Normal Or Open Circuit
MCU 144 5 * L Attachment Flow Valve Current-Cur-
rent Below Normal Or Open Circuit
MCU 144 6 * E Attachment Flow Valve Current-Cur-
rent Above Normal Or Grounded
Circuit
MCU 144 6 * L Attachment Flow Valve Current-Cur-
rent Above Normal Or Grounded
Circuit
ECM 144
2
3 S F Inlet metering valve 1, short circuit
to +24V
ECM 144
2
5 S F Inlet metering valve 1, short circuit
to ground
ECM 144
2
3 S E Inlet metering valve 1, short circuit
to +24V
ECM 144
2
3 S L Inlet metering valve 1, short circuit
to +24V
ECM 144
2
5 S E Inlet metering valve 1, short circuit
to ground
ECM 144
2
5 S L Inlet metering valve 1, short circuit
to ground
ECM 144
2
10 S F Inlet metering valve 1, calculated re-
sistance error
ECM 144
2
2 S F Inlet metering valve 1, faulty
ECM 144
2
7 S F Inlet metering valve 1, stuck
ECM 144
2
8 S F Inlet metering valve 1, plausible
leakage
ECM 144
2
2 S E Inlet metering valve 1, faulty
ECM 144
2
2 S L Inlet metering valve 1, faulty
ECM 144
2
7 S E Inlet metering valve 1, stuck
ECM 144
2
7 S L Inlet metering valve 1, stuck
ECM 144
2
8 S E Inlet metering valve 1, plausible
leakage
ECM 144
2
8 S L Inlet metering valve 1, plausible
leakage
ECM 144
2
10 S E Inlet metering valve 1, calculated re-
sistance error
ECM 144
2
10 S L Inlet metering valve 1, calculated re-
sistance error
continued..........
21
2 SPN 1~