13 mm
Install the belt tensioner.
Torque Value: 43 N*m [32 ft-lb]
FanPulley‐Replacement
Preparatory Steps:
Remove the drive blet.
NOTE: Loosen the capscrews before removing the belt and torque the capscrews after the belt is
installed.
10 mm and 13 mm
Remove the four capscrews, fan and spacer.
Replace the fan pulley.
Torque Values:
8 mm Capscrews-24 N • m [18 ft-lb]
10 mm Capscrews-43 N • m [32 ft-lb]
WaterPump‐Replacement
Preparatory Steps:
Drain the coolant.
Remove the drive belt.