Operation and maintenance manual
www.changlin.com.cn
25/167
pages
ColdWeatherStarting
UsingStartingFluidWithMechanicalorElectricalMeteringEquipment
• Set the throttle at half speed.
• Disengage the driven unit,or if equipped,put the transmission in neutral.
• Activate the switch to open the fuel pump shut-off valve.
• While cranking the engine,inject metered amounts of starting fluid.
• Engine oil pressure must be indicated on the gauge within 30 seconds after starting.
Warning: Never use starting fluid near an open flame, or with a preheater or flame thrower equipment.
This combination can cause an explosion.
Warning: Do not breathe starting fluid fumes. Starting fluid fumes can be harmful to your health.
Caution: Do not use excessive amounts of starting fluid when starting an engine. The use of too much
starting fluid will cause engine damage.
Spray starting fluid into the air cleaner intake while another person cranks the engine.
Warning: Do not ues volatile cold starting aids in underground mine or tunnleoperatons due to the
potential of an explosion. Cheak with the local U. S. Bureau of Mines Inspector for instructions.
StartingProcedure‐AfterExtendedShutdownorOilChange
Complete the following steps after each oil change, or after the engine has been shut off for more than 7
days to make sure the engine receives the correct oil flow through the lubricating oil system:
Disconnect the electrical wire from the fuel pump solenoid valve.
Rotate the crankshaft, using the starting motor,until oil pressure appears on the gauge, or the
warning light goes out.
Connect the electrical wire to the fuel pump solenoid valve.
Start the engine; refer to Normal Starting Procedures in this section.
Refer to Fuel System-Bleeding, Section 5, for instructions to vent the fuel system.