Remove the starting motor.
Install the starting motor in the reverse order or
removal. Torque Value: 43 N*m [32 ft-lb]
Alternator‐Replacement
Disconnect the ground cable from the battery terminal,
identify each electrical wire with a tag indicating
location. Remove the drive belt.
14 mm
Remove the capscrew from the alternator link.
16 mm
Remove the alternator mounting
capscrews. Remove the alternator.