Operation and maintenance manual
www.changlin.com.cn
151/167
pages
10 mm
Remove the starting motor.
Install the starting motor in the reverse order or
removal. Torque Value: 43 N*m [32 ft-lb]
Alternator‐Replacement
Disconnect the ground cable from the battery terminal,
identify each electrical wire with a tag indicating
location. Remove the drive belt.
14 mm
Remove the capscrew from the alternator link.
16 mm
Remove the alternator mounting
capscrews. Remove the alternator.
Position the alternator on the bracket and secure it with the mounting capscrews.