Operation and maintenance manual
www.changlin.com.cn
147/167
pages
22 mm
Remove the plug and regulator
valve.
22 mm
Clean and inspect the bore and regulator valve
before assembly.
Caution: In order to regulate the oil pressure, the
valve must move freely in the bore.
Install the regulator and spring.
Torque Value: 80 N*m [60 ft-lb]
OilCoolerElementandGasket‐ReplacementPreparatorySteps:
• Drain The coolant.
• Remove the oil filter.
Clean all debris from around the oil cooler.