Operation and maintenance manual
www.changlin.com.cn
132/167
pages
10 mm Hex Drive
Caution: If a replacement or repaired pump was
installed, be sure to fill the governor housing with
engine oil before starting the engine. Failure to do
so will result in damage to the governor fly weights.
Remove the access plug.
Oil Capacity
RQVK Governor 750 ML [0.71 Qt]
Install the access plug.
Torque Value: 28 N-m [21 ft-lb]
InjectionPump‐IdleSpeedAdjustment
RQVKGovernor
10 mm Screwdriver and Tachometer
Idle adjustment on automotive pumps requires
setting of the stop screw.
Loosen the locknut and turn the screw
counterclockwise to raise the RPM; clockwise to
decrease the idle speed Tighten the lockscerw.