Operation and maintenance manual
www.changlin.com.cn
129/167
pages
24 mm
Remove the access plug.
Remove the timing pin.
If the timing tooth is not aligned with the timing pin hole,
rotate the pump shaft until the timing tooth aligns.
Reverse the position of the pin so the slot of the pin
will fit over the timing tooth in the pump.
Install and secure the pin with the access plug.