FuelShutoffSolenoid‐ReplacementPreparatorySteps:
• Label and disconnect the wiring.
RQVK Governor Shutoff Solenoid
10 mm
Remove the hitch pin clip, mounting capscrews and
the fuel shutoff solenoid.
Install the new solenoid in reverse order of removal
and connect the wires.
Torque Value: 10 N*m [89 in-lb]
10 mm, 16 mm
Adjust the solenoid linkage as necessary so that the
plunger is magnetically held in with the shutoff lever in
the absolute full run position. Turn the large hex on the
end of the plunger to make adjustments.
injectionPump‐Replacement
Preparatory Steps:
• Clean debris.
• Remove all fuel lines.
• Remove control linkage.
• Remove fuel shutoff solenoid.
• Remove AFC air line
• Remove oil line(s)