Installation, Operation and Service Manual 90DIB500R41IM_FCC02 99.1 211
DIB-500 R4.1 Component replacement
Replacing components of the VAC and alarm system expansion – optional
10. Press softkey 2 to exit the settings.
11. Press softkey 2 twice to exit the main menu.
You have successfully configured the display window of the SC200.
Configuring IP settings of the SC200 (local)
For the proper operation, each SC200 should have corresponding IP settings. The IP
settings will not have been configured upon delivery of the replacement component.
Table 11.32 shows the IP settings that have to be configured for the SC200.
The IP settings must be configured via the controls of the SC200.
Controls of the SC200
When delivered as a spare part, the SC200 will not yet be configured. Once the config-
uration file of the SC200 has been loaded, the controls of the SC200 will be disabled to
prevent configuration adaptations.
Configuring the IP settings of the SC200
Preparation:
The voltage source on site must be switched on.
The network element must be switched on.
Table 11.32 IP settings of SC200
Setting Value
IP address – "IP Address" setting
10.255.255.30
1)
1) When using the SC200 in the second equipment rack with more than four carriers:
10.255.255.29
Network mask – "Subnet Mask" setting 10.255.255.0
Gateway (default gateway) – "Gateway Address"
setting
10.255.255.1