User's Manual
Table Of Contents
- 1 Notes on the document
- 2 Safety regulations
- 3 Product description
- 3.1 Constituents
- 3.1.1 Voltage supply and alarming system
- 3.1.1.1 Terminal block
- 3.1.1.2 Expansion for VAC voltage supply (VAC voltage supply unit)
- 3.1.1.3 Alarm system expansion
- 3.1.1.4 SC200 - optional (VAC or alarm system expansion)
- 3.1.1.5 Alarm input/output module - optional (VAC or alarm system expansion)
- 3.1.1.6 Rectifier module - optional (VAC expansion)
- 3.1.2 E1 connection board
- 3.1.3 Redundancy package with LAN Routing Unit (LRU)
- 3.1.4 On/off switch
- 3.1.5 TIB transceiver module (TETRA Indoor Base)
- 3.1.6 Antenna Coupling System (ACS)
- 3.1.7 Fan unit
- 3.1.8 Cavity coupler (only for the Cavity variant)
- 3.1.9 Redundancy options for the DIB-500 R4.1 or the Base Station Function (BSF)
- 3.1.1 Voltage supply and alarming system
- 3.2 Interfaces
- 3.3 Wiring diagrams
- 3.4 Scope of delivery
- 3.1 Constituents
- 4 Transport and storage
- 5 Setup and commissioning
- 5.1 Safety measures and prerequisites
- 5.2 Tools, aids and materials
- 5.3 Installing equipment racks
- 5.4 Removing the top cover of the mounting frame
- 5.5 Connecting equipment racks (as of 5 carriers)
- 5.6 Connection to the electrical system
- 5.7 Connecting Ethernet cables
- 5.8 Installing the GPS antenna
- 5.9 Installing the GPS protector - optional
- 5.10 Connecting antennas
- 5.11 Connecting external alarm sensors (LSA+)
- 5.12 Connecting external alarms - optional, with VAC or alerting expansion
- 5.13 Mounting the top cover of the equipment rack
- 5.14 Switching on the voltage source
- 5.15 Switching on the DIB-500 R4.1
- 6 Configuration
- 6.1 Configuring the software
- 6.1.1 Work equipment
- 6.1.2 Preparatory measures
- 6.1.3 Deleting the ARP buffer
- 6.1.4 Configuring and generating network configurations via the NMC-515 ConfigurationManager
- 6.1.5 Creating the download repository
- 6.1.6 Adapting IP addresses (with more than one transceiver module)
- 6.1.7 Performing an initial download via NMC-522 DownloadManager
- 6.2 Adjusting a cavity coupler - optional (cavity variant only)
- 6.3 Concluding tasks
- 6.1 Configuring the software
- 7 Function tests and operating surveillance
- 8 Service interruption
- 9 Recommissioning
- 10 Maintenance
- 11 Component replacement
- 11.1 Safety measures and prerequisites
- 11.2 Overview of replacement components and tools, aids and materials
- 11.2.1 Replacing the TIB transceiver module (tools and aids)
- 11.2.2 Replacing the ACS (tools and aids)
- 11.2.3 Replacing components of the fan unit (tools, aids and materials)
- 11.2.4 Replacing the LRU (tools and aids)
- 11.2.5 Replacing the top hat rail power supply unit (tools and aids)
- 11.2.6 Replacing components of the mounting frame/the voltage supply unit (tools, aids and materials)
- 11.2.7 Replacing cavity couplers (tools and aids)
- 11.2.8 Replacing the GPS protector (tools and aids)
- 11.3 Replacing the TIB
- 11.4 Replacing the ACS
- 11.5 Replacing fan unit constituents
- 11.6 Replacing the LRU - optional (redundancy package)
- 11.7 Replacing the top hat rail - optional (redundancy package)
- 11.8 Replacing components of the VAC and alarm system expansion - optional
- 11.9 Replacing cavity couplers - optional (cavity variants only)
- 11.10 Replacing the GPS protector - optional
DIB-500 R4.1 Configuration
Adjusting a cavity coupler – optional (cavity variant only)
148 Installation, Operation and Service Manual 90DIB500R41IM_FCC02 – 99.1
5. Connect the antenna cable to the adapter of the measuring probe. Alternatively,
connect a dummy load (50 Ω), refer to Figure 6.5.
Figure 6.5 Connected measuring equipment
6. Switch on the appropriate measuring equipment and check the AVG (W) and SWR
of the R&S NRT measuring equipment on the display.
7. Enable the carrier to be measured with the command car sw-reset x, x corre-
sponds to carrier no.
➥ The set power is displayed:RF output power on the R&S NRT (display [AVG]).
8. Release the hand wheel on the front of the corresponding cavity coupler.
Adjusting the maximum transmitter output
The handwheel must be adjusted so that the maximum transmitting power is achieved.
When turning the handwheel, the transmitting power climbs to a maximum value and
then drops back down with continued turning. If this happens, turn the cavity coupler
handwheel back in the opposite direction in order to reset the maximum value.
Damage to circulators
When new frequencies are configured via the NMC-515 network management client,
the circulators may be damaged if the cavity coupler(s) is/are not adjusted to these fre-
quencies.
➔ Configure a maximum transmitter output of 1,000 mW via the NMC-515 Configura-
tionManager for the corresponding carrier(s) using the carrier item. This corre-
sponds to a value of 30 dBm.
➔ Adjust the cavity coupler(s) as soon as possible to the corresponding frequencies.
The cavity coupler(s) must be adjusted manually.
9. Use the cavity coupler handwheel to adjust the Tx frequency until the maximum
transmitter output is present at the antenna connection.
Measuring equipment
GPS
Antenna connectors
Antennna cable/dummy load