Installation, Operation and Service Manual 90DIB500R41IM_FCC02 99.1 145
DIB-500 R4.1 Configuration
Adjusting a cavity coupler – optional (cavity variant only)
BSC Command Shell tobs-ppc (Port: 5100)
u
'puc_1'-BSC 10.32.36.17 (5100) >u **
Password OK
User Level: 3
Command is okay
p l -A sbue sbcc 02 01
'puc_1'-BSC 10.32.36.17(5100)>pl-A sbue sbcc 02 01
Appl Node No In Description Parameter value R
------------------------------------------------------SBUE SBCC 02
01 Transmit power of the carrier in mW 600
Command is okay
6. Repeat this work step for all the carriers that have to be set accordingly.
7. Enter the p s sbue sbcc 02 0x 25000 command to set the output power to
25 W;
x corresponds to the carrier number.
The following output is displayed:
'puc_1'-BSC 10.32.36.17 (5100) >p s sbue sbcc 02 01 25000
SBUE SBCC 02 01 Transmit power of the carrier in mW 25000
Command is okay
8. Repeat this work step for all the carriers that have to be set accordingly.
9. Enter the car hw-reset x,
x corresponds to carrier no.
The following output is displayed:
'puc_1'-BSC 10.32.36.17 (5100) >
car hw-reset 1
'puc_1'-BSC 10.32.36.17 (5100) >car hw-reset 1
Command is okay
10. Use the command bsca la to check whether the corresponding carriers have
actually been reactivated.
The following output is displayed:
bsca la
'puc_1'-BSC 10.32.36.17 (5100) >bsca la
Active Alarms of component BSC:
--------------------------------
none
Active Alarms of component CAR1:
--------------------------------
none
Active Alarms of component CAR2:
--------------------------------
none
Command is okay