User's Manual
Table Of Contents
- 1 Notes on the document
- 2 Safety regulations
- 3 Product description
- 4 Requirements concerning the operation room
- 4.1 Infrastructure
- 4.2 Environment
- 4.3 Grounding and overvoltage protection
- 5 Requirements concerning the electrical system
- 6 Requirements concerning the transport network
DIB-500 R4.1 Requirements concerning the electrical system
Voltage supply
32 Site Requirements 90DIB500R41SR_FCC02 – 99.1
5.1.2 Cable specifications for the data and RF cables
The following table lists all the suitable cable types and their specifications.
5.2 Voltage supply
Each equipment rack (apart from the equipment rack(s) of the cavity variant) of the
DIB-500 R4.1 features a connection panel, via which the integrated components are
supplied with voltage and grounded.
Table 5.3 describes the required number of voltage supply connectors on site as a fac-
tor of the voltage supply and the number of carriers. Depending on the voltage supply
and the number of installed transceiver modules, up to two rectifier modules are inte-
grated per equipment rack.
Table 5.1 Cable specifications for data and RF cables
Interfaces Cable type Connector type Impedance
External alarms
CAT5
1)
LSA+
1)
connection via the E1 connection
panel
---
20 to 14 AWG
Screwless terminals for 0.5 to 2-mm
2
–
connection via the alarm input/output
module of the voltage supply unit
(optional)
---
Ethernet CAT5 RJ-45 100 Ω
RF antenna Hybrid Coaxial 2*7/16" connector 50 Ω
Cavity
High Power
Tx transmitter
output / RX
receiver output
FlexibleTx Coaxial N connector 50 Ω
GPS antenna Coaxial
(≤10 dB attenuation)
2)
)
N connector 50 Ω
1) AWG type: Conductor diameters: solid wire 0.40 mm to 0.80 mm, stranded wire 7 x 0.12 mm to 0.32 mm.
Outside diameter: solid conductors and wires 0.70 to 1.60 mm.
Please not that after a connection with ≥ 0.65 mm
2
connection with ≤ 0.65 mm
2
is no longer possible.
2) at 1,500 MHz
Table 5.2 Voltage supply
Voltage supply (rated voltage) | 48 V
DC
(voltage range from 44 to 55 V
DC
)
| optionally 100 V
AC
to 240 V
AC
(frequency: 50 - 60
Hz)
lower voltage supply limit value 44 V
DC
Table 5.3 Required voltage supply connectors
Voltage supply Required voltage supply connectors
Number of carriers 1/2 3/4 5/6 7/8
V
DC
1 x 48 V
DC
2 x 48 V
DC
170 V
AC
- 240 V
AC
(nominal) 1 x 220 V
AC
2 x 220 V
AC
100 V
AC
- 170 V
AC
(nominal) 1 x 110 V
AC
2 x 110 V
AC
3 x 110 V
AC
4 x 110 V
AC