User's Manual

Table Of Contents
Site Requirements 90DIB500R41SR_FCC02 99.1 23
DIB-500 R4.1 Requirements concerning the operation room
Infrastructure
Hybrid antenna coupling
system
Return loss at all connections 22 dB
Isolation between Tx inputs 22 dB
Cavity antenna coupling
system
VSWR at all Tx inputs 1.3
Isolation at minimum carrier distance 10 dB
Table 4.2 Requirements for external antenna coupling systems.
Constituent Property/demand Value/Value range
Table 4.3 Requirements for the individual components of external antenna coupling systems
Constituent Property/demand Value/Value range
Isolator Impedance 50 Ω
Insertion loss at 25 °C 0.5 dB (recom-
mended)
Isolation at 25 °C 50 dB
VSWR 1.2
Input power at the Tx input 100 W (nominal)
Reverse power for 10 minutes 60 W
without VSWR monitoring
permanently
60 W
VSWR monitoring For recording faults at the
antenna system, the operator
must implement a separate
VSWR monitoring system.
---
Duplex filter Impedance 50 Ω
Insertion loss (Rx) at 25 °C 1.1 dB (required)
Insertion loss (Tx) at 25 °C 1.1 dB (recom-
mended)
3rd order intermodulation
component (IM 3)
2 x 43 dBm, 1 MHz distance -135 dBc
Input power at antenna connection and Tx input according to the fed
input power
Isolation between all frequency bands 80 dB
Return loss at all connections 22 dB
Bandpass filter Impedance 50 Ω
Insertion loss (Rx) at 25 °C 1.1 dB (required)
Insertion loss (Tx) at 25 °C 1.1 dB (recom-
mended)
3rd order intermodulation
component (IM 3)
2 x 43 dBm, 1 MHz distance -135 dBc
Input power at the Tx input according to the fed
input power
Rejection at upper stopband 55 dB
Return loss at all connections 22 dB