Installation, Operation and Service Manual 90DIB500R41IM_FCC02 99.1 41
DIB-500 R4.1 Product description
Constituents
Figure 3.11 shows the front view of a rectifier module. The following table describes
these indicators in detail.
Figure 3.11 Rectifier module (front view)
3.1.2 E1 connection board
The E1 connection board provides connections for the internal and external E1 wiring
and for alarms.
The external E1 interfaces A1 and B1 (refer to Figure 3.12, are routed via an E1 relay
and serve to connect further network elements connected in the form of a ring. If a TIB
transceiver module fails, the E1 relay is disabled and the incoming E1 connection is
directly looped on to the next network element.
Figure 3.12 shows the top view of the E1 connection board. The following table
describes these indicators in detail.
Figure 3.12 E1 connection board (top view)
Table 3.13 Legend: front view of rectifier module
No. Constituent Description
1 "Major Alarm" LED LED for signalling major alarms.
2 "Minor Alarm" LED LED for signalling "minor" alarms.
3 LED "Power" LED for signalling of the voltage supply.
4 Mounting screw ---
3
1
2
4
Table 3.14 Legend: E1 connection board (top view)
No. Description
1 External alarm inputs (LSA+)
2 External E1 connections (LSA+)
3 E1 relay for looping through connected E1 connections