User's Manual

Table Of Contents
DIB-500 R4.1 Product description
Constituents
38 Installation, Operation and Service Manual 90DIB500R41IM_FCC02 99.1
3.1.1.4 SC200 – optional (V
AC
or alarm system expansion)
The SC200 is a hardware component and used for monitoring the voltage supply and
for alarm signalling and is installed in the mounting frame.
Through the SC200, external alarms can be collected via the freely-configurable, digital,
alarm inputs of the alarm input / output module and reported via the Network Manage-
ment System. In addition, product alarms can be signalled via the digital alarm outputs
of the alarm input/output module.
Figure 3.7 shows the front view of the system controller. The following table describes
these indicators in detail.
Figure 3.7 Front view of system controller
Figure 3.8 shows the display window of the system controller. The following table
describes these in detail.
Figure 3.8 System controller display window
Table 3.8 Legend: front view of system controller
No. Constituent Colour Description
1 Display window
---
Display window for visualization.
2 Softkey Softkey. The respective function depends on
the display in the display window.
3 Navigation keys Keys for navigation and menu inputs.
4 USB USB interface
5 Softkey Softkey. The respective function depends on
the display in the display window.
6 LED "Power" green LED for signalling of the voltage supply.
7 "Minor Alarm" LED yellow LED for signalling "minor" alarms.
8 "Critical/Major Alarm" LED red LED for signalling "major" and "critical" alarms.
21 3
5
8
7
6
4
1
2
3