User's Manual

Table Of Contents
DIB-500 R4.1 Component replacement
Replacing the TIB
178 Installation, Operation and Service Manual 90DIB500R41IM_FCC02 99.1
Risk of damage
Risk of damage due to high weight (19 kg). The TIB may fall when pushing it in/pulling it
out and damage other components.
When pulling the TIB out, additionally support it from below with your other hand.
3. Now cautiously pull the component out along the holder.
The removal of the TIB has been completed.
11.3.2 Installing the TIB
The procedure for installing the TIB is described below.
Proceed as follows to install the TIB:
Preparation:
The preparatory measures must be completed, refer to Table 11.10 on page 175.
The tools and aids must be available, refer to section 11.2.1 on page 172.
You need the mounting screws removed with the component.
Carry out the following steps:
Risk of damage
Risk of damage due to high weight (19 kg). The TIB may fall when pushing it in/pulling it
out and damage other components.
When pulling the TIB out, additionally support it from below with your other hand.
Risk of injury
The equipment rack features sharp edges on the inside. Risk of injury if you do not wear
protective gloves.
Always wear protective gloves for the following process steps.
1. Cautiously slide in the component along the holding plate from the front until the
connecting pins on the rear of the component slide into the openings provided.
2. Retighten the attachment screws of the component on the front of the equipment
cabinet. Use a Torx screwdriver size TX 25 for this purpose.
3. Properly reconnect all the cables to the component.