User's Manual

Table Of Contents
Problem Possible cause Troubleshooting
"ALM" LED is on Checking operating state in the NMC-511
FaultManager
Restarting the base station (duration
approx. three to five minutes)
BSCU, CHU defective Electrical connection to back-
plane defective
Check connection to backplane
Power supply missing Check power supply
Fan unit not (completely)
operational
Electrical connection to back-
plane defective
Check connection to backplane
PSU/PSM defective with V
AC
power supply
Check PSU/PSM
"ALM" LED is on Checking operating state in the NMC-511
FaultManager
Check DIP switches at the rear side of
the fan unit
"FAN 1-6" LED flashes Checking operating state in the NMC-511
FaultManager
Check fan
Troubleshooting
DIB-R5 flexibleTx
85Operation Manual 90DIBR5flexibleTxOM02 - 1.2