User Manuals Parkinson's Disease Sleep Assessment System MS100-IFU-EN V1.
Revision History Version number V1.0 V1.
Manufacturer: GYENNO Technologies CO., LTD. Address: A805 A806,Shenzhen Institute of Industry-University-Research of HUST,No.9 Yuexing 3rd Road,Science Park,Nanshan District,Shenzhen,518000,P.R.China Tel.: 0086-755-86724035 Email: service@gyenno.com Website: www.gyenno.
Catalog 1 Intended use .............................................................................................................................7 2 Security Information ............................................................................................................... 7 3 Overview ................................................................................................................................... 9 3.1 Introduction ...............................................................
Table of Contents Table 1 Equipment front ......................................................................................................................................10 Table 2 Data Box Description .............................................................................................................................. 10 Table3 Working conditions ..................................................................................................................................
Figure Catalog Figure 1 HYPNOS ................................................................................................................................................... 9 Figure 2 Equipment Composition ......................................................................................................................... 9 Figure 3 Front of the device ................................................................................................................................
Description of terms in this manual Warning Caution Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in invalid data collecting ,damage to the equipment or invalid operation. Information necessary to be known before using the equipment.
5 Do not exceed the maximum load of this equipment. 6 Do not disassemble or modify this equipment by yourself.
3 Overview 3.1 Introduction The device collects the sleep data of Parkinson's disease patients through the built-in sensor module and uploads the data through the wireless communication module. After further analysis and processing, the measurement results of sleep quality, nocturnal movement symptoms and early morning movement symptoms can be obtained. Figure 1 HYPNOS 3.2 Composition This device consists of side A, side B, data box and 5V3A adapter.
3.2.1 Equipment front 2 1 3 5 Figure 3 Front of the device Part Description 1 A side screen printing "GYENNO" 2 A side screen printing 3 Built-in memory foam on A side 4 A-side silkscreened sit down icon 5 B-side data cable and data box connection Table 1 Equipment front 3.2.
3.3 Working conditions Conditions Parameters Ambient temperature 5 ℃ ~ +40 ℃ Relative Humidity 10% ~ 85% RH (no condensation) Atmospheric pressure 70 kPa ~ 106 kPa Internal power supply 3.7 V Supply Voltage External power supply 5V 900 mAh 3A Table3 Working conditions 3.4 Storage conditions Conditions Parameters Ambient temperature -20 ℃ ~ +50 ℃ Relative Humidity 10% ~ 93% RH (no condensation) Atmospheric pressure 70 kPa ~ 106 kPa Table 4 Storage conditions 3.
Medical device Manufacturer Table 5 Symbols used in this equipment 4 Specifications and parameters 4.1 Terminology Sleep efficiency: refers to the efficiency of the patient's sleep detected by this device. Total sleep time: The total time the patient sleeps as detected by this device. Sleep latency: refers to the sleep latency of the patient detected by this device. Number of night-time wake-ups: The number of night-time wake-ups of the patient detected by the device.
5.2 Specification 870MM Wraparound width 8MM R 58MM Figure 5 Dimensional schematic Main parameters Indicators Overall size 870 mm(L) * 670 mm(W) * 8 mm(D) Overall weight ≈500 g Charging form DC input Maximum load capacity 200kg Wireless Wireless Standards 802.11 b/g/n Frequency range 2400 MHz ~ 2483.5 MHz Antenna Type Built-in antenna Table 6 Specification parameters 4.
5.1 Prepare for first time use This device needs to be used with the device mobile application - HYPNOS APP, Please download the "HYPNOS" APP from the following channels and install it, after completing the installation, according to the "HYPNOS" APP user guide to complete the registration. This device needs to be used with the device mobile application – “HYPNOS”APP. Please search for “HYPNOS” in the appropriate mobile application store, download and install it.
Figure 6 Equipment assembly 5.2.2 Placement of cushion bed As shown in the picture below, please place the assembled device, under the sheet, with the top of the device flush with the shoulder. Figure 7 Equipment placement position 5.2.3 Open and Close Turn on: Insert the adapter into the data box, then connect the power supply and the device indicator lights up. Turn off: Disconnect the adapter from the power supply and the device indicator goes off. Attention 1 Adapter requirement: 5V 3A.
2 Discarded equipment and power cords must be disposed of in accordance with local regulations or they may cause contamination. 5.2.4 Equipment Monitoring This device is turned on and the person lies down on the device to automatically start the detection. Figure 8 Equipment Inspection 5.2.5 Transferring data The data recorded by the device is saved in the device and uploaded in bulk with the wireless network configured. 1) Turn the unit on before preparing to transfer data.
5.2.6 View Results The measurement results of this device can be viewed in the mobile application "HYPNOS" APP "Data", including the data of sleep quality, nighttime symptoms, early morning movement symptoms, etc. by date. Caution If the corresponding measurement results cannot be viewed, it may be due to the following reasons. 1 After the measurement cycle is completed, no data is uploaded or the uploaded data is incomplete due to lack of wireless network connection or other reasons.
Fault Type Possible causes and treatment methods 3 The QR code is lost or broken and cannot be scanned Please call customer service for a solution. 1 Enter the wrong wireless network password Please enter the correct wireless network password and try again. 2 Failed to connect to Device exits fast connection due to timeout Please try again following the section "Connecting to the wireless network wireless network".
4824 public low-voltage supply networks connected directly to the home. Harmonic emission GB 17625.1 Voltage fluctuation / flicker emission GB17625.2 Class A Conformity Table 9 For all equipment and systems Guidelines and Manufacturer's Statement - Electromagnetic Immunity the device is expected to be used in the following specified electromagnetic environment, and the purchaser or user of the device should ensure that it is used in such electromagnetic environment.
Guidelines and Manufacturer's Statement - Electromagnetic Immunity The device is expected to be used in the following specified electromagnetic environment, and the purchaser or user of the device shall ensure that it is used in such electromagnetic environment. Immunity test IEC 60601 test level Conformity level Electromagnetic Environment-Guide Portable and mobile RF communications equipment should not be used closer to any part of the (equipment or system), Radio Frequency Conduction GB/T 17626.
are 1,8 MHz to 2,0 MHz, 3,5 MHz to 4,0 MHz, 5,3 MHz to 5,4 MHz, 7 MHz to 7,3 MHz, 10,1 MHz to 10,15 MHz, 14 MHz to 14,2 MHz, 18,07 MHz to 18,17 MHz, 21,0 MHz to 21,4 MHz, 24,89 MHz to 24,99 MHz, 28,0 MHz to 29,7 MHz and 50,0 MHz to 54,0 MHz.
if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna.
The equipment comes with an 1annual warranty. (hereinafter referred to as "the Company") is not responsible for direct, indirect or final damage and delays caused by.