Single Phase Soft Starters Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.
Contractor: P.O.
Contractor: P.O.: Engineer: Project Name: Single Phase Soft Starters Unit Tag: Dimensional Data Single Phase 2.94” 5.30 LE D 1.96” 3.80 3.80 3.16 0.65 3.16 Mounting Bracket Approved Mounting Positions LED 1 2 LED 3 4 Not Approved LED 7 5 6 8 LED The manufacturer works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice.
Contractor: P.O.: Engineer: Project Name: Single Phase Soft Starters Unit Tag: Physical Characteristics SureStart Model Storage Temperature, oF [oC] Case Material IP Rating Line Conductor, AWG Line Conductor Strip Length, in. [mm] Minimum Line Conductor Length, in. [mm] Line Terminal Tightening Torque, in-lbs [N-m] Start Winding & Compressor Common, AWG Single Phase SS1B08-16 SS1B16-32 -40 [-40] to 185 [85] ABS Flameproof UL-94 V0 IP207 14 - 6 14 - 6 14 - 6 0.47 [12] 0.47 [12] 0.47 [12] 15.7 [400] 15.
Contractor: P.O.
Contractor: P.O.: Engineer: Project Name: Single Phase Soft Starters Unit Tag: SureStart Mode of Operation ,QLWLDO 3RZHU RQ 'HOD\ W VHF 6XUH6WDUW &RQWLQXRXV 0RWRU 'LDJQRVWLFV )DXOW 'HOD\ EDVHG RQ W\SH RI IDXOW 127( )DXOW 'HOD\ LV WKH F\FOH ZDLWLQJ WLPH EHIRUH D UH VWDUW LV DWHPSWHG 5HIHU WR /(' IODVK FRGHV IRU DQ\ IDXOW GLDJQRVWLFV 5HIHU WR 2SHUDWLQJ &KDUDFWHULVWLFV WDEOH IRU FXW RII YROWDJH UDQJHV The manufacturer works continually to improve its products.
Contractor: P.O.: Engineer: Project Name: Single Phase Soft Starters Unit Tag: SureStart Single Phase LED Flash Codes Led Flash Codes Flash Code (Slow Flash (1 / 3 secs): Lockout on Over current) A Red LED indicator will flash under the following conditions. - [NOTE: LED fault indicator is turned off in normal running mode.
Contractor: P.O.: Engineer: Project Name: Single Phase Soft Starters Unit Tag: Declaration of Conformity SureStart technology has been tested and certified under the following standards that apply. For United States, Canada, & Mexico UL 508/ CSA 22.
Contractor: P.O.: Engineer: Project Name: Single Phase Soft Starters Unit Tag: Definitions Case Material – SureStart enclosure material Line conductor – Wiring that connects to the “run winding” and “active” terminations on single phase SureStart. Line Conductor Strip Length – This is the length of insulation stripped away in order to properly insert into the SureStart. Line Terminal Tightening Torque – The necessary torque needed to secure line conductors to the SureStart.
Contractor: P.O.: Engineer: Project Name: Single Phase Soft Starters Unit Tag: Notes The manufacturer works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification.