Datasheet
Table Of Contents
- Description
- Features
- Ordering Information
- Key Parameters
- Speed Grade
- Address Table
- Pin Descriptions
- Input/Output Functional Descriptions
- Pin Assignments
- Registering Clock Driver Specifications
- On DIMM Thermal Sensor
- Functional Block Diagram
- 4GB, 512Mx72 Module(1Rank of x8)
- 8GB, 1Gx72 Module(1Rank of x4) - page1
- 8GB, 1Gx72 Module(1Rank of x4) - page2
- 8GB, 1Gx72 Module(2Rank of x8) - page1
- 8GB, 1Gx72(2Rank of x8) - page2
- 16GB, 2Gx72 Module(2Rank of x4) - page1
- 16GB, 2Gx72 Module(2Rank of x4) - page2
- 16GB, 2Gx72 Module(2Rank of x4) - page3
- 32GB, 4Gx72 Module(4Rank of x4) - page1
- 32GB, 4Gx72 Module(4Rank of x4) - page2
- 32GB, 4Gx72 Module(4Rank of x4) - page3
- 32GB, 4Gx72 Module(4Rank of x4) - page4
- 32GB, 4Gx72 Module(4Rank of x4) - page5
- Absolute Maximum Ratings
- AC & DC Operating Conditions
- AC & DC Input Measurement Levels
- Vref Tolerances
- AC and DC Logic Input Levels for Differential Signals
- Differential signal definition
- Differential swing requirements for clock (CK - CK) and strobe (DQS-DQS)
- note : Rising input differential signal shall become equal to or greater than VIHdiff(ac) level and Falling input differential signal shall become equal to or less than VIL(ac) level.
- Single-ended requirements for differential signals
- Differential Input Cross Point Voltage
- Slew Rate Definitions for Single-Ended Input Signals
- Slew Rate Definitions for Differential Input Signals
- AC & DC Output Measurement Levels
- Overshoot and Undershoot Specifications
- Refresh parameters by device density
- Standard Speed Bins
- Environmental Parameters
- IDD and IDDQ Specification Parameters and Test Conditions
- IDD Specifications (Tcase: 0 to 95oC)
- Module Dimensions

Rev. 1.0 / May. 2014 25
Absolute Maximum Ratings
Absolute Maximum DC Ratings
Notes:
1. Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the
device. This is a stress rating only and functional operation of the device at these or any other conditions above
those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rat
-
ing conditions for extended periods may affect reliability.
2. Storage Temperature is the case surface temperature on the center/top side of the DRAM. For the measurement
conditions, please refer to JESD51-2 standard.
3. VDD and VDDQ must be within 300mV of each other at all times; and VREF must not be greater than
0.6XVDDQ,When VDD and VDDQ are less than 500mV; VREF may be equal to or less than 300mV.
DRAM Component Operating Temperature Range
Notes:
1. Operating Temperature TOPER is the case surface temperature on the center / top side of the DRAM. For mea-
surement conditions, please refer to the JEDEC document JESD51-2.
2. The Normal Temperature Range specifies the temperatures where all DRAM specifications will be supported. Dur-
ing operation, the DRAM case temperature must be maintained between 0 - 85
o
C under all operating conditions.
3. Some applications require operation of the DRAM in the Extended Temperature Range between 85
o
C and 95
o
C
case temperature. Full specifications are guaranteed in this range, but the following additional conditions apply:
a. Refresh commands must be doubled in frequency, therefore reducing the Refresh interval tREFI to 3.9 µs. It
is also possible to specify a component with 1X refresh (tREFI to 7.8µs) in the Extended Temperature Range.
Please refer to the DIMM SPD for option availability
b. Manual Self-Refresh mode with Extended Temperature Range capability (MR2 A6 = 0b and MR2 A7 = 1b).
DDR3 SDRAMs support Extended Temperature Range and please refer to component datasheet and/or the
DIMM SPD for tFEFI requirements in the Extended Temperature Range.
Absolute Maximum DC Ratings
Symbol Parameter Rating Units Notes
VDD
Voltage on VDD pin relative to Vss
- 0.4 V ~ 1.80 V V 1,3
VDDQ
Voltage on VDDQ pin relative to Vss
- 0.4 V ~ 1.80 V V 1,3
V
IN
, V
OUT
Voltage on any pin relative to Vss
- 0.4 V ~ 1.80 V V 1
T
STG
Storage Temperature
-55 to +100
o
C1, 2
Temperature Range
Symbol Parameter Rating Units Notes
T
OPER
Normal Operating Temperature Range
0 to 85
o
C 1,2
Extended Temperature Range
85 to 95
o