Manual

USERPROGRAMMINGMODE
UserProgrammingModeOptions
Abbreviation Parameter Description
DO Day Override The timer’s day override setting
RT Regeneration
Time
The time of day that the system
will regenerate (meter delayed,
timeclock, and day-of-week
systems)
H Feed Water
Hardness
The hardness of the inlet water
- used to calculate system
capacity for metered systems
RC or SF Reserve Capacity The xed reserve capacity
CD Current Day The current day of week
NOTE:Someitemsmaynotbeshowndependingontimer
conguration.Thetimerwilldiscardanychanges
andexitUserModeifanybuttonisnotpressedfor
sixtyseconds.
UserProgrammingModeSteps
1. Press the Up and Down buttons for ve seconds while in
service, and the time of day is NOT set to 12:01 PM.
2. Use this display to adjust the Day Override. This option
setting is identied by “DO” in the upper left hand corner of
the screen.
3. Press the Extra Cycle button. Use this display to adjust the
Regeneration Time. This option setting is identied by “RT”
in the upper left hand corner of the screen.
4. Press the Extra Cycle button. Use this display to adjust the
Feed Water Hardness. This option setting is identied by
“H” in the upper left hand corner of the screen.
Range: 1-199 hardness
5. Press the Extra Cycle button. Use this display to adjust the
Fixed Reserve Capacity. This option setting is identied by
“RC” or "SF" in the upper left-hand Corner of the screen.
6. Press the Extra Cycle button. Use this display to set the
Current Day of the Week. This option setting is identied by
“CD” in the upper left hand corner of the screen.
7. Press the Extra Cycle button to end User Programming
Mode.
8 • JL10 Fleck SXT Timer