Manual

12.RegenerationTime
Press the Extra Cycle button. Use this display to set the
Regeneration Time. This setting species the time of day the
control will initiate a delayed, manually queued, or day override
triggered regeneration. This option setting is identied by “RT”
in the upper left hand corner of the screen. Use the Up and
Down buttons to adjust the value as needed.
13.RegenerationCycleStepTimes
Press the Extra Cycle button. Use this display to set the
Regeneration Cycle Step Times. The different regeneration
cycles are listed in sequence based on the valve type selected
for the system, and are identied by an abbreviation in the
upper left-hand corner of the screen. The abbreviations used
are listed below. If the system has been congured with the
“OTHER” valve type, the regeneration cycles will be identied
as R1, R2, R3, R4, R5, and R6. Each cycle step time can be
set from 0 to 199 minutes. Setting a cycle step time to 0 will
cause the control to skip that step during regeneration, but
keeps the following steps available. Use the Up and Down
buttons to adjust the value as needed. Press the Extra Cycle
button to accept the current setting and move to the next
parameter.
Abbreviation Cycle Step
BD Brine Draw
BF Brine Fill
BW Backwash
RR Rapid Rinse
SV Service
Range: 0-199 minutes
14.DayofWeekSettings
Press the Extra Cycle button. Use this display to set the
regeneration schedule for a system congured as a Day of
Week control. The different days of the week are identied as
D1, D2, D3, D4, D5, D6, and D7 in the upper left-hand corner
of the display. Set the value to “ON” to schedule a regeneration
or “OFF” to skip regeneration for each day. Use the Up and
Down buttons to adjust the setting as needed. Press the Extra
Cycle button to accept the setting and move to the next day.
Note that the control requires at least one day to be set to
“ON.” If all 7 days are set to “OFF”, the unit will return to Day
One until one or more days are set to “ON.”
MASTER PROGRAMMING MODE
cont inued
15.CurrentDay(DisplayCodeCD)
Press the Extra Cycle button. Use this display to set the current
day on systems that have been congured as Day of Week
controls. This setting is identied by “CD” in the upper left-hand
corner of the screen. Use the Up and Down buttons to select
from Day 1 through Day 7.
16.FlowMeterType(DisplayCodeFM)
Press the Extra Cycle button. Use this display to set the type
of ow meter connected to the control. This option setting is
identied by “FM” in the upper left-hand corner of the screen.
Use the Up and Down buttons to select one of the 7 available
settings.
t0.7 Fleck 3/4” Turbine Meter
P0.7 Fleck 3/4” Paddle Wheel Meter
t1.0 Fleck 1” Turbine Meter
P1.0 Fleck 1” Paddle Wheel Meter
t1.5 Fleck 1 1/2” Turbine Meter
P1.5 Fleck 1 1/2” Paddle Wheel Meter
P2.0 Fleck 2” Paddle Wheel Meter
GEn Generic/Other Meter
17.MeterPulseSetting(DisplayCodeK)
Press the Extra Cycle button. Use this display to specify the
meter pulse setting for a non-standard ow meter. This option
setting is identied by “K” in the upper left-hand corner of
the screen. Use the Up and Down buttons to enter the meter
constant in pulses per unit volume.
18.EndofMasterProgrammingMode
Press the Extra Cycle button to save all settings and exit
Master Programming Mode.
Fleck SXT Timer JL10 • 7