5600 SXT Valve Downflow Automatic Water Softeners Operation Manual Read all instructions carefully before operation. #54711 Rev.
Performance and Specifications Meter Initiated Model Twin Tank Models 5600SXTM-835-50 5600SXTM-844-75 5600SXTM-948-100 5600SXTM-1035-100 5600SXTM-1047-125 5600SXTM-1054-150 5600SXTM-1252-200 5600SXTM-1450-250 @15lb/cf Cabinet Models CAB5600SXTM-835-50 CAB5600SXTM-1035-100 Capacity at Various Salt Dosages grains @6lb/cf @10lb/cf(1) @3lb/cf Service Flow Rate(2) USGPM Backwash Flow Rate USGPM Resin Volume cu. ft.
Control Operation During Programming The control will only enter the Program Mode with the valve in Service. While in the Program Mode, the control will continue to operate normally, monitoring water usage and keeping all displays up to date. Control programming is stored in memory permanently, eliminating the need for battery back-up power. Meter Immediate Control A meter immediate control measures water usage and regenerates the system as soon as the calculated system capacity is depleted.
Installation Instructions All government codes and regulations governing the installation of these devices must be observed. CAUTION: If the ground from the electrical panel or breaker box to the water meter or underground copper pipe is tied to the copper water lines and these lines are cut during installation of the Noryl bypass valve and/or poly pipe, an approved grounding strap must be used between the two lines that have been cut in order to maintain continuity.
Installation Instructions Figure 3 4. Attach the bypass valve to the control valve. Connect the inlet and outlet of the water softener to the plumbing in the house. The control valve must not be submitted to temperatures above 71°C (110°F). When sweat fittings are used, to avoid damaging the control valve, solder the threaded copper adapters to the copper pipe and then, using Teflon tape, screw the assembly into the bypass valve.
Operating Instructions Figure 4 The valve has been pre-programmed with factory settings as follows: Regeneration Cycle Step Programming 1. Backwash ..................................10 minutes 2. Brine Rinse ..................................60 minutes 3. Rapid Rinse ................................10 minutes 4. Brine Refill ..................................
User Programming Mode Options Abbreviation Parameter DO Day Override RT Regeneration Time H Feed Water Hardness RC Reserve Capacity CD Current Day Description The timer’s day override setting THIS IS AN OPTION ONLY. PLEASE DO NOT ADJUST BEFORE CONSULTING AN AUTHORIZED DEALER.
Error Codes Note: Error codes appear on the In Service display Error Code Probable Cause Recover and Resetting [Err 0] Drive motor is stalled Unplug the unit from the power source [Err 1] Drive motor is running continuously When power is restored to the unit, the Err _ display code clears. If the condition causing the error has not been resolved the Err _ code reappears in the four digit display. Do not attempt to troubleshoot this problem any further.
Manual Regeneration Cycle If you run out of softened water because of inadequate regeneration frequency, inadequate reserve capacity, power failure or unusually high water usage, you can initiate a manual regeneration simply by pressing the extra cycle button. The softener will now automatically complete a regeneration cycle and return to service. If possible, avoid water use during the regeneration cycle.
Maintenance Instructions Checking the Salt Level Check the salt level monthly. Remove the lid from the cabinet or brine tank, make sure salt level is always above the brine level (you should not be able to see water). Adding Salt Use only clean salt labeled for water conditioner use, such as crystal, pellet, nugget, button or solar. The use of rock salt is discouraged because it contains insoluble silt and sand which build up in the brine tank and can cause problems with the system’s operation.
Trouble Shooting Guide 1. 2. 3. 4.
GUARANTEE HYDROTECH guarantees that your new water conditioner is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble-free service. FIVE YEAR COMPLETE PARTS GUARANTEE HYDROTECH will replace any part which fails within 60 months from date of manufacture, provided the failure is due to a defect in material or workmanship.