5600SXT Valve Carbon & Multi-Media Filter Operation Manual Read all instructions carefully before operation. #54701 Rev.
Performance and Specifications Hydrotech Taste & Odor Filter (Carbon) Item Number Model Number Media Pipe Size Service Flow Rate Peak Flow Rate Backwash Flow Rate Mineral Tank size Shipping Weight 7615 7616 7617 5600SXTM-847AC 5600SXTM-948AC 5600SXTM-1054AC cu. ft. (litres) 0.75 (21) 1.00 (28) 1.50 (42) inches (mm) 3/4 (19) 3/4 (19) 3/4 (19) 4.0 (15) 4.0 (15) 5.0 (19) USGPM (LPM) 5.0 (19) 6.0 (23) 7.0 (27) 3.5 (13) 4.0 (15) 5.
Control Operation During Programming The control will only enter the Program Mode with the valve in Service. While in the Program Mode, the control will continue to operate normally, monitoring water usage and keeping all displays up to date. Control programming is stored in memory permanently, eliminating the need for battery back-up power. Meter Immediate Control A meter immediate control measures water usage and regenerates the system as soon as the calculated system capacity is depleted.
Installation Instructions All government codes and regulations governing the installation of these devices must be observed. CAUTION: If the ground from the electrical panel or breaker box to the water meter or underground copper pipe is tied to the copper water lines and these lines are cut during installation of the Noryl bypass valve and/or poly pipe, an approved grounding strap must be used between the two lines that have been cut in order to maintain continuity.
2. Attach the bypass valve to the control valve. Connect the inlet and outlet of the water filter to the plumbing in the house. The control valve must not be submitted to temperatures above 71°C (110°F). When sweat fittings are used, to avoid damaging the control valve, solder the threaded copper adapters to the copper pipe and then, using Teflon tape, screw the assembly onto the bypass valve. CAUTION: Do not use pipe thread compound as it may attack the material in the valve body. 3.
Operating Instructions Figure 3 The valve has been pre-programmed with factory settings as follows: Capacity between Regenerations............1,500 gallons Regeneration Cycle Step Programming 1. Backwash ............................................6 2. Brine Rinse ............................................0 3. Rapid Rinse ..........................................4 4. Brine Refill ............................................
User Programming Mode Options Abbreviation Parameter Description DO Day Override RT Regeneration Time The time of day that the system will regenerate (meter delayed, timeclock, and day-of-week systems) RC Reserve Capacity The fixed reserve capacity CD Current Day The timer’s day override setting THIS IS AN OPTION ONLY. PLEASE DO NOT ADJUST BEFORE CONSULTING AN AUTHORIZED DEALER. The current day of week NOTES: Some items may not be shown depending on timer configuration.
Set treated water capacity (only available in metered systems) 1. Set time of day to 12:01 PM. 2. 3. 4. 5. Press Extra Cycle button to exit the time of day display. Press and hold the Up and Down buttons together until the programming icon replaces the service icon. Press Extra Cycle button till “C” is displayed in the upper left corner of the screen. Use Up and Down buttons to set the amount of treated water that can flow through the unit before a regeneration is required. 650 gallon capacity 6.
Operating Instructions Water Pressure Your water filter is designed to operate under normal water pressures from 20 psi to 100 psi. Regeneration and Automatic Bypass Water filters are factory set to regenerate at 11:00 p.m. during a period of little or no water use. The regeneration cycle lasts approximately 15 minutes, after which filtered water service is restored. While regeneration is taking place,"raw water" automatically bypasses the filter if required.
Trouble Shooting Guide PROBLEM 1. Filter bleeds taste and odor or sediment 2. Filter fails to regenerate CAUSE CORRECTION A. Bypass valve is open B. Electrical service to unit has been interrupted C. Defective or stripped media bed A. Close bypass valve D. Quality of water has worsened any change D. Have water sample analyzed to determine B. Assure permanent electrical service (check fuse, plug or switch) C. Replace media E. Filter capacity too small E.
GUARANTEE HYDROTECH guarantees that your new water conditioner is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble-free service. FIVE YEAR COMPLETE PARTS GUARANTEE HYDROTECH will replace any part which fails within 60 months from date of manufacture, provided the failure is due to a defect in material or workmanship.