5600SE Valve Carbon & Multi-Media Filter Operation Manual Read all instructions carefully before operation.
Performance and Specifications Hydrotech Taste & Odor Filter (Carbon) Item Number Model Number Media Pipe Size Service Flow Rate Peak Flow Rate Backwash Flow Rate Mineral Tank size Shipping Weight 7615 7616 7617 5600SEM-847AC 5600SEM-948AC 5600SEM-1054AC cu. ft. (litres) 0.75 (21) 1.00 (28) 1.50 (42) inches (mm) 3/4 (19) 3/4 (19) 3/4 (19) 4.0 (15) 4.0 (15) 5.0 (19) USGPM (LPM) 5.0 (19) 6.0 (23) 7.0 (27) 3.5 (13) 4.0 (15) 5.
Control Operation During Programming The control will only enter the Program Mode with the valve in Service. While in the Program Mode, the control will continue to operate normally, monitoring water usage and keeping all displays up to date. Control programming is stored in memory permanently, eliminating the need for battery back-up power. Control Operation During a Power Failure During a power failure, all control displays and programming will be stored for use upon power re-application.
1. Determine the best location for your water filter, bearing in mind the location of your water supply lines, drain line and 120 volt AC electrical outlet. Subjecting the softener to freezing or temperatures above 110°F (43° C) will void the warranty. NOTE: Some units are shipped with the media bed in separate bags.
Operating Instructions Service Indicator: Flow Indicator: Valve in Service - Dot On Extra Cycle Tonight - Flashing Dot Flashing Dot With Water Flow P.M. Indicator Set Up Button Set Down Button Figure 4 The Valve has been pre-programmed with factory settings as follows: Regeneration Step Cycle Programming 1. 2. 3. 4.
Operating Instructions Whenever the valve is in Service the current time of day can be set, the control programmed, or an extra regeneration initiated at any time. Service Indicator: Flow Indicator: Valve In Service - Dot On Extra Cycle Tonight - Flashing Dot Flashing Dot with Water Flow P.M. Indicator Set Up Button Set Down Button Push either the Up or Down Set Button once to adjust Time of Day Display by one digit.
Program Mode Indicator: Program Mode Entered - Dot On Set Up Button Extra Cycle Button Set Down Button 1. The first option setting display that appears in the Program Mode is Treated Water Capacity. Using the Set Up or Down Buttons, set the amount of treated water that can flow through the unit before a regeneration is required. For Example: 650 Gallons Capacity Service Program • 650 Flow P.M. 2. Push the Extra Cycle Button. The second option setting display that appears is Regeneration Time.
Operating Instructions Water Pressure Your water filter is designed to operate under normal water pressures from 20 psi to 100 psi. Regeneration and Automatic Bypass Water filters are factory set to regenerate at 11:00 p.m. during a period of little or no water use. The regeneration cycle lasts approximately 15 minutes, after which filtered water service is restored. While regeneration is taking place,"raw water" automatically bypasses the filter if required.
Trouble Shooting Guide PROBLEM 1. Filter bleeds taste and odor or sediment CAUSE CORRECTION A. Bypass valve is open B. Electrical service to unit has been interrupted C. Defective or stripped media bed D. Quality of water has worsened any change 2. Filter fails to regenerate A. Close bypass valve B. Assure permanent electrical service (check fuse, plug or switch) C. Replace media D. Have water sample analyzed to determine E. Filter capacity too small E.
9
GUARANTEE HYDROTECH guarantees that your new water conditioner is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble-free service. FIVE YEAR COMPLETE PARTS GUARANTEE HYDROTECH will replace any part which fails within 60 months from date of manufacture, provided the failure is due to a defect in material or workmanship.