2510 Valve nextSand Turbidity & Sediment Filter Operation Manual Read all instructions carefully before operation.
Flow Rates USGPM (for ultrafine particle removal) Model # Service Peak Backwash Service Peak Backwash 4.0 5.0 5 5.6 7.0 5 2510CC-847NEXTSF-75 • • • • • Flow Rates for Typical Application USGPM Installation Space Fiberglass Tank Size Inches Shipping Weight Lbs 10 x 10 x 57 8 X 47 95 2510CC-948NEXTSF-100 5.0 7.0 7 7.1 8.8 7 11 x 11 x 58 9 X 48 145 2510CC-1054NEXTSF-150 7.0 8.0 8 8.7 10.9 8 12 x 12 x 64 10 X 54 213 2510CC-1252NEXTSF-200 10.0 12.0 12 12.6 15.
Installation and Start-up Procedure Installation Instructions CAUTION: If the ground from the electrical panel or breaker box to the water meter or underground copper pipe is tied to the copper water lines and these lines are cut during installation of a Noryl bypass valve and/or poly pipe, an approved grounding strap must be used between the two lines that have been cut in order to maintain continuity.
Start-Up Instructions Water-only backwash 1. Check that the correct backwash (BW) flowrate has been determined based on the water temperature. (See table below) 2. Allow the tank to slowly fill with water from the bottom. This is most easily accomplished by setting the control valve to the backwash position and partially opening the inlet valve until water flows from the drain line. 3. Allow the media to soak for at least 30 minutes. 4.
Programming Backwash Controls Setting the 24-Hour Timer Press and hold the red button in to disengage the drive gear. Turn the large dial until the actual time of day is opposite the time of day pointer. Release the red button to re-engage the drive gear. Service Position Indicator Dot Determining The Backwash Frequency 24 Hour Gear Manual Regeneration Knob The following table can be used to help determine the frequency of regeneration.
maintenance Instructions Maintenance of your new water filter requires very little time or effort but it is essential. Regular maintenance will ensure many years of efficient and trouble free operation. Care of All Water Filters To retain the attractive appearance of your new water filter, clean occasionally with a mild soap solution. Do not use abrasive cleaners, ammonia or solvents. Never subject your filter to freezing or to water temperatures above 120°F.
Trouble Shooting Guide PROBLEM CAUSE CORRECTION 1. Filter bleeds taste and odor or sediment A. Bypass valve is open B. Electrical service to unit has been interrupted C. Defective or stripped media bed D. Quality of water has worsened E. Filter capacity too small F. Filter not backwashing enough G. Excessive water usage H. Tabs on skipper wheel not out A. Close bypass valve. B. Assure permanent electrical service (check fuse, plug or switch). C. Replace media. D.
GUARANTEE HYDROTECH guarantees that your new water conditioner is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble-free service. FIVE YEAR COMPLETE PARTS GUARANTEE HYDROTECH will replace any part which fails within 60 months from date of manufacture, provided the failure is due to a defect in material or workmanship.