S T E A M B O I L E R C O N T R O L S
Water Feeder – Residential
Model VXT-24 and VXT-120
•
Universal Compatibility
• Works with all major probe and float-type low
water cut-offs.
•
Digital Feed Counter
• Continually tracks and displays the amount of
make-up water fed into the boiler – essential for
diagnosing system leaks
that can severely shorten
the life of the boiler.
•
Call-For-Feed Indicator
• Illuminates during feed signal from the LWCO
•
Programmable Feed Delay Settings (30 Sec. to 10 Min)
• Helps prevent flooded boilers. Allows time for condensate to return to boiler before
initiating feed cycle – ensuring that additional water is needed.
•
Programmable Feed Amount Settings (LWCO and 1-5 Gal)
• With the LWCO setting selected, the VXT raises the water level to low water
cut-off. The 1 to 5 Gallon settings can be selected to fine-tune the VXT to restore the
normal operating water level above the low water cut-off.
•
Manual Feed Button
• Allows for manual feeds with the touch of a button.
•
Underfeed Protection
• If one feed cycle is not sufficient to restore boiler
operation, the VXT will delay and feed one additional cycle.
•
Lock-Out Flood Protection
• Locks-out after two consecutive feed cycles
to prevent flooding.
MODEL VOLTAGE DESCRIPTION/OPERATION
VXT-24 24 VAC Upon a feed signal from low water cut-off, the VXT feeder delays (from
VXT-120 120 VAC 30 seconds to 10 minutes) to allow condensate to return to boiler. If make-up
water is required after the delay period, the VXT will initiate a feed cycle. The
VXT can be set to feed to the level of the low water cut-off or can be set from 1
to 5 gallons to raise the water level above the cut-off to the normal operating
level. The digital feed counter tracks all water fed into the boiler including water
added using the Manual Feed Button.
U.S. Patent No. 6,688,329
Specifications VXT-24 VXT-120
Power Consumption 10 VA 15 VA
Max. Fluid Temperature 150° F 150° F
Flow Rate 1 GPM 1 GPM
Fittings 1/2" Sweat 1/2" Sweat
See VXT video at www.hydrolevel.com