Technical Specifications
HS2T2ZZV HS2T3ZZV
HS2T4ZZV
Dimensions: WxHxD Dimensions: WxHxD Dimensions: WxHxD
26.25” x 24” x 10” 26.25” x 24” x 10” 26.25” x 32.5” x 10”
Number of Zones: Number of Zones: Number of Zones:
2 3 4
e HSPS190MZH requires a Zoning By Zone Valve-Zone Panel. Zone Panels for the HSPS190MZH
are available in 1 or 2 Water Delivery Temperatures and up to 4 Zones. Zone Panels connect direct-
ly with the HSPS190MZH panel via 1” Quick Connects. Zoning options are available in 2, 3, and 4
Zones.
HSPS190MZH Zone Panels
Up to 4 Zones
SKU: 6651220
SKU: 6651221
SKU: 6651222
Number of Thermostats:
2 3 4
Number of Thermostats: Number of Thermostats:
2 Temp
2 Temp Panels are used when you have multiple emitter types that require signicantly dierent
water deliver temperatures. For example, if you have tubing in concrete and baseboard, you would
need two water delivery temperatures. If you had two dierent emitter types that are similar in water
delivery temperatures such as baseboard and radiator, you would not need a two temp panel.