SKU: 6651121 HSPS190MTH Multi Zone, High Temp Panel 190K BTU Zoning By Telestats-Telestats on Manifold Required* Up to 4 Zones*
The HSPS190MTH is a multi zone, high temperature integrator panel for radiant heat. This panel is designed for Tubing in Concrete emitters such as Embedded Concrete or Staple Down/Pour Over, Baseboard, Radiators, or Staple Up. It features Primary/Secondary plumbing, expansion tank, brass y-strainer, supply and return pressure/temperature gauges, and other components necessary to ensure your system runs smoothly. This panel requires telestats on your manifold for zoning.
24.00” 26.25” 10.
J H A I G B L This system view features the HSPS190MTH multi zone integrator panel (Zoning By Telestats), HS199CON gas boiler and a 3POS manifold with Telestats. Your system may have a different boiler and number of loops from what is shown. This is to illustrate what a typical system would look like when completed.
Zoning By Telestats M D Telestats are used for zoning. They are placed on your hydronic manifold and control flow through each individual loop on a zone. Telestats can be paired up to 4 loops per zone. When zoning by telestats, you must have a telestat on every single loop of your manifold. You must have a minimum of 3 loops per zone, as this will help prevent short cycling. You can achieve multiple zones on one manifold.